HH Solutions HOBO MX2300 Series Скачать руководство пользователя страница 3

HOBO

 

MX2300

 

Series

 

Data

 

Logger

 

Manual

 

1

800

LOGGERS

 

3

 

www.onsetcomp.com

 

Logger

 

Components

 

and

 

Operation

 

   

Mounting

 

Holes:

 

Use

 

the

 

holes

 

at

 

the

 

top

 

and

 

bottom

 

of

 

the

 

logger

 

to

 

mount

 

it

 

(see

 

Deploying

 

and

 

Mounting

 

the

 

Logger

).

 

Alarm

 

LED:

 

This

 

LED

 

blinks

 

red

 

every

 

4

 

seconds

 

when

 

an

 

alarm

 

is

 

tripped

 

(unless

 

Show

 

LED

 

is

 

disabled

 

as

 

described

 

in

 

Configuring

 

the

 

Logger

).

 

Status

 

LED:

 

This

 

LED

 

blinks

 

blue

 

every

 

4

 

seconds

 

when

 

the

 

logger

 

is

 

logging

 

(unless

 

Show

 

LED

 

is

 

disabled

 

as

 

described

 

in

 

Configuring

 

the

 

Logger

).

 

If

 

the

 

logger

 

is

 

waiting

 

to

 

start

 

logging

 

because

 

it

 

was

 

configured

 

to

 

start

 

“On

 

Button

 

Push”

 

or

 

with

 

a

 

delayed

 

start,

 

it

 

will

 

blink

 

every

 

8

 

seconds.

 

Start

 

Button:

 

Press

 

this

 

button

 

to

 

wake

 

up

 

the

 

logger;

 

both

 

the

 

alarm

 

and

 

status

 

LEDs

 

will

 

blink.

 

Once

 

the

 

logger

 

is

 

awake,

 

press

 

this

 

button

 

to

 

move

 

it

 

to

 

the

 

top

 

of

 

the

 

devices

 

list

 

in

 

the

 

app.

 

Press

 

this

 

button

 

for

 

3

 

seconds

 

to

 

start

 

or

 

stop

 

the

 

logger

 

when

 

it

 

is

 

configured

 

to

 

start

 

or

 

stop

 

“On

 

button

 

push”

 

(see

 

Configuring

 

the

 

Logger

).

 

Both

 

LEDs

 

will

 

blink

 

four

 

times

 

when

 

you

 

press

 

the

 

button

 

to

 

start

 

or

 

stop

 

logging.

 

Press

 

this

 

button

 

for

 

10

 

seconds

 

to

 

reset

 

a

 

password

 

(see

 

Setting

 

a

 

Password

).

 

External

 

Sensor:

 

This

 

is

 

the

 

external

 

probe

 

attached

 

to

 

the

 

bottom

 

of

 

the

 

logger

 

that

 

measures

 

temperature

 

or

 

temperature/RH.

 

The

 

MX2302A

 

logger

 

has

 

one

 

external

 

sensor

 

that

 

measures

 

both

 

temperature

 

and

 

RH

 

and

 

the

 

MX2304

 

logger

 

has

 

one

 

sensor

 

that

 

measures

 

temperature

 

only.

 

The

 

MX2303

 

logger

 

(shown

 

at

 

left

 

above)

 

has

 

two

 

external

 

temperature

 

sensors;

 

the

 

left

 

sensor

 

is

 

channel

 

1

 

and

 

the

 

right

 

sensor

 

is

 

channel

 

2.

 

Vent:

 

The

 

RH

 

sensor

 

is

 

located

 

behind

 

the

 

vent

 

(MX2301A

 

model

 

only).

 

Downloading

 

the

 

App

 

and

  

Connecting

 

to

 

a

 

Logger

 

Install

 

the

 

app

 

to

 

connect

 

to

 

and

 

work

 

with

 

the

 

logger.

 

1.

 

If

 

you

 

are

 

using

 

an

 

iPhone®

 

or

 

iPad®:

 

Download

 

HOBOmobile

 

from

 

the

 

App

 

Store®.

 

If

 

you

 

are

 

using

 

an

 

Android

 

phone

 

or

 

tablet:

 

Download

 

HOBOconnect

 

from

 

Google

 

Play™.

 

2.

 

Open

 

the

 

app

 

and

 

enable

 

Bluetooth

 

in

 

the

 

device

 

settings

 

if

 

prompted.

 

3.

 

Press

 

the

 

button

 

on

 

the

 

logger

 

to

 

wake

 

it

 

up.

 

4.

 

Tap

 

the

 

Devices

 

in

 

the

 

app.

 

(In

 

HOBOmobile,

 

tap

 

Loggers

 

at

 

the

 

top

 

of

 

the

 

screen.)

 

Tap

 

the

 

logger

 

in

 

the

 

app

 

to

 

connect

 

to

 

it.

 

If

 

the

 

logger

 

does

 

not

 

appear

 

or

 

if

 

it

 

is

 

having

 

trouble

 

connecting,

 

follow

 

these

 

tips:

 

 

Make

 

sure

 

the

 

logger

 

is

 

“awake”

 

by

 

pressing

 

the

 

start

 

button.

 

The

 

alarm

 

and

 

status

 

LEDs

 

will

 

blink

 

once

 

when

 

the

 

logger

 

wakes

 

up.

 

You

 

can

 

also

 

press

 

the

 

button

 

a

 

second

 

time

 

to

 

bring

 

it

 

to

 

the

 

top

 

of

 

the

 

list

 

if

 

you

 

are

 

working

 

with

 

multiple

 

loggers.

 

 

Make

 

sure

 

the

 

logger

 

is

 

within

 

range

 

of

 

your

 

mobile

 

device.

 

The

 

range

 

for

 

successful

 

wireless

 

communication

 

is

 

approximately

 

30.5

 

m

 

(100

 

ft)

 

with

 

full

 

line

of

sight.

 

 

If

 

there

 

are

 

several

 

loggers

 

in

 

the

 

area,

 

move

 

the

 

logger

 

to

 

a

 

location

 

with

 

fewer

 

loggers.

 

Interference

 

can

 

sometimes

 

occur

 

when

 

numerous

 

loggers

 

are

 

in

 

one

 

location.

 

 

If

 

your

 

device

 

can

 

connect

 

to

 

the

 

logger

 

intermittently

 

or

 

loses

 

its

 

connection,

 

move

 

closer

 

to

 

the

 

logger,

 

within

 

sight

 

if

 

possible.

 

 

If

 

the

 

logger

 

appears

 

in

 

the

 

app,

 

but

 

you

 

cannot

 

connect

 

to

 

it,

 

close

 

the

 

app

 

and

 

power

 

cycle

 

the

 

mobile

 

device.

 

This

 

forces

 

the

 

previous

 

Bluetooth

 

connection

 

to

 

close.

 

Once

 

connected

 

to

 

the

 

logger

 

you

 

can

 

select

 

one

 

of

 

the

 

following

 

actions:

 

 

Configure

 

in

 

HOBOmobile

 

or

 

 

in

 

HOBOconnect.

 

Select

 

logger

 

settings

 

and

 

load

 

them

 

onto

 

the

 

logger

 

to

 

start

 

logging.

 

See

 

Configuring

 

the

 

Logger

.

 

 

Readout

 

in

 

HOBOmobile

 

or

 

 

in

 

HOBOconnect.

 

Download

 

logger

 

data.

 

See

 

Reading

 

Out

 

the

 

Logger

.

 

 

Full

 

Status

 

Details

 

in

 

HOBOmobile

 

or

   

in

 

HOBOconnect.

 

Check

 

information

 

about

 

the

 

logger.

 

In

 

HOBOconnect,

 

access

 

some

 

of

 

the

 

actions

 

described

 

in

 

this

 

section.

 

 

Start

 

Logging

 

in

 

HOBOmobile

 

or

 

 

and

 

then

 

 

in

 

HOBOconnect.

 

Select

 

this

 

option

 

to

 

begin

 

logging

 

(if

 

the

 

logger

 

is

 

configured

 

to

 

start

 

“On

 

Button

 

Push”

 

as

 

described

 

in

 

Configuring

 

the

 

Logger

).

 

 

Stop

 

Logging

 

in

 

HOBOmobile

 

or

 

 

and

 

then

 

 

in

 

HOBOconnect.

 

Stop

 

the

 

logger

 

from

 

recording

 

data.

 

This

 

overrides

 

any

 

Stop

 

Logging

 

settings

 

described

 

in

 

Configuring

 

the

 

Logger

.

 

 

Page

 

Logger

 

LED

 

in

 

HOBOmobile

 

or

 

 

and

 

then

 

 

in

 

HOBOconnect.

 

Press

 

and

 

hold

 

this

 

option

 

to

 

illuminate

 

the

 

alarm

 

and

 

status

 

LEDs

 

for

 

4

 

seconds.

 

 

Logger

 

Password

 

in

 

HOBOmobile

 

or

   

and

 

then

 

 

in

 

HOBOconnect.

 

Select

 

this

 

to

 

create

 

a

 

password

 

for

 

the

 

logger

 

that

 

will

 

be

 

required

 

if

 

another

 

mobile

 

device

 

attempts

 

to

 

connect

 

to

 

it.

 

To

 

reset

 

a

 

password,

 

connect

 

to

 

the

 

logger,

 

tap

 

Set

 

Logger

 

Passkey,

 

and

 

select

 

Reset

 

to

 

Alarm

 

LED

 

Mounting

 

Holes

 

Start

 

Button

 

External

 

Sensor

 

Status

 

LED

 

MX2303

 

model

 

shown

 

Vent

 

MX2301A

 

model

 

shown

 

Содержание HOBO MX2300 Series

Страница 1: ...C 40 to 158 F exposure to conditions below 20 C 4 F or above 95 RH may temporarily increase the maximum RH sensor error by an additional 1 Accuracy 2 5 from 10 to 90 typical to a maximum of 3 5 including hysteresis at 25 C 77 F below 10 RH and above 90 RH 5 typical Resolution 0 01 Drift 1 per year typical Response Time typical to 90 of change Temperature Without Solar Radiation Shield With RS1 M R...

Страница 2: ...luetooth Always On disabled Faster logging intervals and statistics sampling intervals burst logging remaining connected with the app excessive downloads and paging may impact battery life Memory MX2301A and MX2302A 128 KB 63 488 measurements maximum MX2303 MX2304 and MX2305 128 KB 84 650 measurements maximum Full Memory Download Time Approximately 60 seconds may take longer the further the device...

Страница 3: ...e app to connect to it If the logger does not appear or if it is having trouble connecting follow these tips Make sure the logger is awake by pressing the start button The alarm and status LEDs will blink once when the logger wakes up You can also press the button a second time to bring it to the top of the list if you are working with multiple loggers Make sure the logger is within range of your ...

Страница 4: ...t the next even interval as determined by the selected logging interval On Button Push Logging will begin once you press the button on the logger for 3 seconds On Date Time Logging will begin on a date and time you specify Select the date and time In HOBOmobile tap Done Tap Done or Save 8 Tap Stop Logging and select the options for when logging will end a Choose one of two memory options When Memo...

Страница 5: ...s 30 minute period 7 Tap Done or Save and repeat steps 3 6 for the other sensor if desired 8 In the configuration settings select one of the following options to determine how the alarm indications are cleared Logger Reconfigured The alarm indication will display until the next time the logger is reconfigured Sensor in Limits The alarm icon indication will display until the sensor reading returns ...

Страница 6: ...ults for the sampling period recorded at each logging interval The following statistics can be logged for each sensor The maximum or highest sampled value The minimum or lowest sampled value An average of all sampled values and The standard deviation from the average for all sampled values For example a logger is configured with both the temperature and RH sensors enabled and the logging interval ...

Страница 7: ...to view a larger version of the graph or share the file In HOBOconnect Tap the HOBO Files icon and select the file to view it Tap and then to export and share the data Data can also be uploaded automatically to HOBOlink Onset s web based software via the app or the MX gateway For details see the app user s guide and see the HOBOlink help for details on working with data in HOBOlink Logger Events T...

Страница 8: ...s 2 year typical with a logging interval of 1 minute but may be extended to 5 years when the logger is configured with Bluetooth Always On disabled Expected battery life varies based on the ambient temperature where the logger is deployed the logging or sampling interval frequency of offloading and connecting to the mobile device number of channels that are active and use of burst mode or statisti...

Страница 9: ...ircuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC C...

Отзывы: