HH Electronics TESSEN TNA-1800SA Скачать руководство пользователя страница 6

TNA ACTIVE LINE ARRAY SYSTEM

LIVE SOUND & INSTALLATION

Designed and Engineered in the UK by HH Electronics LTD. 

© 2022 HH Electronics Ltd

STATUS

POWER

LIMIT

PROTECT

SIGNAL

INPUT

INPUT SENSITIVITY

+10dB

0dB

XOVER

PHASE

70

75

80

85

90

95

100

110

120

FULL RANGE

LINK OUT

FULL 

RANGE

LINK OUT

XOVER

DELAY

0

9

8

7

6

5

4

3

2

1

0

ms

0

.9

.8

.7

.6

.5

.4

.3

.2

.1

0

180°

4
5

9

7

10

11

1

2

6

3

CONTROL PANEL

7. PHASE SWITCH:

 Pressing this switch reverses the phase of the onboard subwoofer output with respect to signal input. Signals from the 

LINK OUT

 are un-affected. 

8. LINE INPUT: 

A balanced XLR line input, suitable for balanced or non-balanced line level signals.

Please refer to the block diagram on page 8.

11. DELAY: 

Applies an audio delay to the internal loudspeaker to time align the subwoofer to your system. It can also be used to implement a 

cardioid function when used with the 

PHASE CONTROL

 

(7) 

and another TNA-1800SA. The 

DELAY

 duration is set via the two onboard 

controls with left of the two providing millisecond increments and microseconds from the right control. 

6. LIMITER INDICATOR: 

Illuminates just before the amplifier begins to clip. Adjust the 

INPUT SENSITIVITY 

and/or signal level from your 

source so the indicator illuminates only briefly during peaks in the music. Continuous limiting of the signal will result in reduced audio quality and 
dynamic content.

5. PROTECT INDICATOR: 

This illuminates if a fault condition occurs. The amplifier will shut down to prevent further damage with normal 

operation resuming once the fault condition has been rectified.

4. SIGNAL INDICATOR: 

Illuminates to indicate that there is a signal present at the 

INPUT

.

9. LINK OUT: 

A balanced XLR line output, suitable for sending a line level signal to an external device.

Please note: The Line input is not suitable for a mic-level signal.

1. INPUT SENSITIVITY: 

This control sets the input sensitivity of the TNA-1800SA. Turned fully anti-clockwise, the system will accept a nominal 

+10dB signal such as that from a high output mixing console, whereas when set to 0dB it is more suited to lower-level inputs such as those from 
PA link outs. +10dB sensitivity is recommended for most setups. Increase if you need more volume.

2. XOVER CONTROL:

 Adjust the full range frequency limit of the sub from 70Hz(fully anti-clockwise) to 120Hz(fully clockwise). 

A full range setting is also included to aid setup and troubleshooting.

3. POWER INDICATOR:

 Illuminates when the unit is connection to the mains power supply and switched on. 

10. LINK OUT SWITCH:

 With the Link switch disabled  

(FULL RANGE) the 

LINK OUT

 signal is sourced from the 

LINE INPUT

. With 

LINK

 switch enabled 

 

 (XOVER) a HPF filter is applied to the 

LINK OUT

 set to the frequency determined by the 

XOVER

 Control (2).

The 

DELAY

 control does not affect the audio from the 

LINK OUT

.

6

EN

EN

2

1

3

8

SUB-Cabinet 1
SUB-Cabinet 2

PHASE MISALIGNMENT AT THE CROSS OVER POINT 

PHASE ALIGNMENT AT THE CROSS OVER POINT 

WOOFER PHASE ALIGNMENT

Содержание TESSEN TNA-1800SA

Страница 1: ...TNA 1800SA 18 ACTIVE SUBWOOFER USER MANUAL LIVE SOUND INSTALLATION DESIGNED AND ENGINEERED IN THE UK WWW HHELECTRONICS COM...

Страница 2: ..._______ SAFETY WARNINGS 1 _______________________________ COVER PAGE 23 25 ___________________________ 7 _______________________________ CONTROL PANEL CONTINUED 9 _______________________________ SYSTE...

Страница 3: ...de feu n exposez pas cet appareil a la pluie ou a l humidite Avant d utiliser cet appareil lisez les advertissments supplentaires situes dans le guide Para evitar corrientazos o peligro de incendio no...

Страница 4: ...lity to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time 9 An apparatus with Class I construction shall be connected...

Страница 5: ...ghly in order to get the best performance and reliability from your HH product Bars And Clubs APPLICATIONS Live Sound Reinforcement The TNA 1800SA Active subwoofer features a HH designed 18 inch low f...

Страница 6: ...INDICATOR This illuminates if a fault condition occurs The ampli er will shut down to prevent further damage with normal operation resuming once the fault condition has been recti ed 4 SIGNAL INDICAT...

Страница 7: ...tion of the system 17 HEAT SINK As with the ventilation slot please allow for free and unrestricted air ow 18 SAFETY INFORMATION powerCON is a registered trademark of Neutrik AG All other trademarks a...

Страница 8: ...eered in the UK by HH Electronics LTD 2022 HH Electronics Ltd FREQUENCY RESPONSE 8 BLOCK DIAGRAM XOVER FULL RANGE LINK OUT SOURCE LINK OUT INTERNAL LOUD SPEAKER INPUT SENSITIVITY DSP XOVER DSP DSP DEL...

Страница 9: ...2120SA Active 3ch Subwoofer 6x TNA 2051 Passive Full Range Satellites 1x TNA 1800SA 18 inch Active Subwoofer 9 EN EN TNA 2051 6 TNA 2051 5 TNA 2051 4 TNA 2051 3 TNA 2051 2 TNA 2051 1 TNA 1800SA TNA 2...

Страница 10: ...XLR Output Connector Balanced Male XLR Switchable Full Range Xover Signal Indicators Power Signal Present Clip Indicator Protect Controls Input sensitivity Crossover frequency Phase Switch Variable D...

Страница 11: ...aune c Le fil marron doit tre branch sur la borne rep r e par la lettre L ou par la couleur rouge 17 Note pour le Royaume Uni Si les couleurs des fils du c ble d alimentation ne correspondent pas aux...

Страница 12: ...n est pas adapt e un signal de niveau micro 1 SENSIBILIT D ENTR E Cette commande r gle la sensibilit d entr e du TNA 1800SA Tourn e fond dans le sens inverse des aiguilles d une montre le syst me acc...

Страница 13: ...our les fentes de ventilation veuillez permettre une libre circulation d air et sans restriction 16 FENTES DEVENTILATION Une libre circulation d air est n cessaire pour un fonctionnement r gulier et a...

Страница 14: ...rn ausgesetzt werden und es muss darauf geachtet werden dass keine mit Fl ssigkeiten gef llte Gegenst nde wie z B Blumenvasen auf dem Ger t abgestellt werden Sollen den Benutzer auf dasVorhandensein w...

Страница 15: ...0 Hz ganz im Uhrzeigersinn an 9 LINK OUT Ein symmetrischer XLR Line Ausgang geeignet zum Senden eines Line Pegel Signals an ein externes Ger t Eine vollst ndige Bereichseinstellung ist ebenfalls entha...

Страница 16: ...System ein und aus Stellen Sie sicher dass der INPUT SENSITIVITY Regler beim Einschalten auf Minimum steht powerCON ist ein eingetragenes Warenzeichen der Neutrik AG Alle anderen Warenzeichen sind Eig...

Страница 17: ...ducto va a ser instalado en una unidad de rack use alg n tipo de apoyo trasero 18 Este aparato el ctrico no debe ser sometido a ning n tipo de goteo o salpicadura y se debe tener cuidado para no poner...

Страница 18: ...almente en el sentido antihorario a 120 Hz totalmente en sentido horario 4 INDICADOR DE SE AL Se ilumina para indicar que hay una se al presente en la ENTRADA 6 INDICADOR DEL LIMITADOR Se ilumina just...

Страница 19: ...entilaci n permita un ujo de aire libre y sin restricciones PowerCON es una marca registrada de Neutrik AG Todas las dem s marcas comerciales son propiedad de sus respectivos due os 16 RANURAS DEVENTI...

Страница 20: ...om liga o de prote o N o anule a finalidade de seguran a da ficha polarizada ou do tipo terra Uma ficha polarizada possui duas l minas uma mais larga que a outra Uma ficha do tipo terra tem duas l min...

Страница 21: ...5 INDICADOR DE PROTE O Acende se ocorrer uma condi o de falha O ampli cador ser desligado para evitar mais danos com a retomada da opera o normal assim que a condi o de falha for corrigida 4 INDICADO...

Страница 22: ...o de ar livre e irrestrito PowerCON uma marca registrada da Neutrik AG Todas as outras marcas registradas s o de propriedade de seus respectivos propriet rios 13 INTERRUPTOR DE ALIMENTA O Liga e desli...

Страница 23: ...STEM LIVE SOUND INSTALLATION Designed and Engineered in the UK by HH Electronics LTD 2022 HH Electronics Ltd 9 I 20 6 1 5 4 7 12 b N 15 16 8 3 10 11 c L 17 2 13 14 a E 18 19 OSHA OSHA 2000m 2000m 21 C...

Страница 24: ...0dB XOVER PHASE 70 75 80 85 90 95 100 110 120 FULL RANGE LINK OUT FULL RANGE LINK OUT XOVER DELAY 0 9 8 7 6 5 4 3 2 1 0 ms 0 9 8 7 6 5 4 3 2 1 0 0 180 4 5 9 7 10 11 1 2 6 3 1 TNA 1800SA 10dB 2 70Hz 12...

Страница 25: ...TION DESIGNED AND ENGINEERED IN THE UK POWER CONSUMPTION 350 WATTS POWER CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION LE RISQUE DE D CHARGE LECTRIQUE NE S OUVRENT PAS CAUTION DO NOT BLOCK VENT...

Страница 26: ...REVISION 1 00 Model number Serial number Place of purchase Date of purchase hhelectronics www hhelectronics com hhelectronics hhelectronics...

Отзывы: