background image

 

 

Publication No. 498-048 

FAX 

::  +44 (0)1629 824284 

::  +44 (0)1629 824613 

Email 

::  Ravenstor Road 

    Wirksworth 
    DERBYSHIRE 
    DE4 4FY 
::  www.HGIgenerators.com 
::  [email protected] 

Operation & Maintenance  

Manual 

 

Welf-Air Super Compact 

Installation Guide

 

WASC60 Series 

Содержание WASC60 Series

Страница 1: ...8 FAX 44 0 1629 824284 44 0 1629 824613 Email Ravenstor Road Wirksworth DERBYSHIRE DE4 4FY www HGIgenerators com info HGIgenerators com Operation Maintenance Manual Welf Air Super Compact Installation...

Страница 2: ......

Страница 3: ...Croft Technical Department Nov 2012 Document Authorisation Document History Date Version Author Reason for change 10 03 11 A C Coulton First Release for Cabin Install 26 11 12 B Draft 1 M Crowfoot Upd...

Страница 4: ......

Страница 5: ...Harrington Generators International Ltd Welf Air Super Compact Installation 498 048 Issue C WASC60 Series 3000 rpm Diesel Generator for Welf Air Cabins...

Страница 6: ......

Страница 7: ...ard Installation 1 4 Alternative Installation 2 6 Cabin Outlet Ventilation 3 7 Cabin Distribution Board 3 8 Access and Clearance 3 9 Contact Details 3 10 General Dimensions 5 11 Installation Diagrams...

Страница 8: ......

Страница 9: ...are optional It is important that heat wrap is fitted so that operatives do not burn themselves It is down to the individual installation engineer s to ensure that the unit is safely and correctly ins...

Страница 10: ...assemble Care must be taken to make a gas tight seal when connecting the exhaust and that it is adequately insulated To protect the exhaust and prevent potential burns to operatives wrap the exhaust l...

Страница 11: ...ntilation Adequate sized louvre panels should be built into the cabin doors or walls for generator ventilation purposes It is recommended that the typical free inlet should provide at least 230cm2 Car...

Страница 12: ...it 8 0 Access and Clearance The generator needs to occupy a clear space within the cabin compartment Water pipes pumps tanks waste pipes and other items should be mounted away from the generator The c...

Страница 13: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 5 498 048 Issue C 10 0 General Dimensions...

Страница 14: ......

Страница 15: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 7 498 048 Issue C 11 0 Installation Diagrams...

Страница 16: ......

Страница 17: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 9 498 048 Issue C 12 0 DC Wiring...

Страница 18: ......

Страница 19: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 11 498 048 Issue 13 0 AC Wiring...

Страница 20: ......

Страница 21: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 13 498 048 Issue 14 0 Remote Start Wiring...

Страница 22: ......

Страница 23: ...Installation Guide Harrington Generators International Ltd Welf Air Super Compact Installation 15 498 048 Issue 15 0 Remote Start Lead...

Страница 24: ......

Страница 25: ...Check the exhaust extension is securely fitted and that there is a gas tight seal around the joins Check that the pipe clamps are fitted and tight 5 If alternative method used check the air outlet du...

Страница 26: ......

Страница 27: ...Harrington Generators International Ltd Welf Air Super Compact Installation 498 048 Issue C Notes...

Страница 28: ......

Страница 29: ......

Страница 30: ...E DE4 4FY www HGIgenerators com info HGIgenerators com Important This manual contains important safety information If you lose this manual please contact HGI Limited with the Serial Number of your gen...

Отзывы: