HFT PurgEye 200 IP65 Скачать руководство пользователя страница 9

PAGE 9 

STaTUS IcoNS

When necessary, the following four status icons will be displayed 

on the right hand side of the display.

Display units

This will be either ‘PPM’ or ‘%’ for oxygen concentration values. 

Press and hold ‘display’ button to change the display units. 

Battery status

When the PurgEye

® 

200  IP65  is  running  on  batteries  a  filled 

battery icon will be displayed. A low battery warning is indicated 

by an empty battery  icon   .
When an external power supply is connected and the battery is 

charging, the battery symbol will animate from empty to full. A mains 

plug  icon       

will be displayed when the battery is fully charged.

Pump status

When the sample pump is enabled, you will see an arrow icon  

scrolling to the right, if the PurgEye

®

 has detected that there is 

insufficient flow for an accurate reading then this icon will flash to 

indicate a possible inaccurate reading.
NoTE: Insufficient flow could be due to a blocked filter or very long 

sample pipes. Filters must always be used and should be replaced 

on a regular basis. The PurgEye

®

 1000 Weld Purge Monitor

®

 should 

be considered, if you are having problems with long lengths of purge 

gas sample tubes.

Alarm status

Whilst the alarm is active, a speaker icon       will flash on the 

display. If the mute function is activated then the speaker icon will 

show a cross 

beside it.

Содержание PurgEye 200 IP65

Страница 1: ...USER INSTRUCTIONS PurgEye a Family Series of Weld Purge Monitors PurgEye 200 IP65 WELD PURGE MONITOR with PurgeNet...

Страница 2: ...t HFT All rights reserved This publication may not be reproduced by any means without the written permission of Huntingdon Fusion Techniques HFT All logos names trademarks are the property and ownersh...

Страница 3: ...ting started 4 5 Connections 6 Controls 7 8 Status icons 9 PurgeNet interface 10 Care and maintenance 11 Warning 12 Other languages 13 Customer support and worldwide care 14 Warranty 15 Address and co...

Страница 4: ...l and the PurgEye 200 IP65 controls 2 Switch on the PurgEye 200 See item 3 below Continue to learn the controls 3 Connect the green tubing to the filter white connector at the rear of the instrument 4...

Страница 5: ...xhaust filter Purge gas input from purge zone PurgeNet Charging lead Status icons Adjust button Adjust button Display button Function button Display STANDBY PPM 10 10 The monitor will display dashes u...

Страница 6: ...ith USB Charging To charge your PurgEye 200 IP65 connect the supplied charger to the PurgeNet connector or directly into the 3 pin connector on the PurgEye 200 IP65 Your PurgEye 200 IP65 is designed t...

Страница 7: ...g dropping below the alarm set point then the mute feature is automatically disabled allowing the sounder to activate next time the alarm is activated by a reading above the alarm set point value Disp...

Страница 8: ...ata can then be transferred via the usb Adjust Pressing this button will increase the currently displayed set point by 10 ppm Holding this button will cause the set point to increase in 100 ppm steps...

Страница 9: ...ug icon will be displayed when the battery is fully charged Pump status When the sample pump is enabled you will see an arrow icon scrolling to the right if the PurgEye has detected that there is insu...

Страница 10: ...ries are connected to the PurgeNet interface connection they will be automatically detected by your PurgEye 200 IP65 and extra menu options may appear as required Language Support Current support The...

Страница 11: ...and free from grease and other contaminants Keep welding enclosures clean and clear of non essential items that could out gas when hot Please Note Permanent damage to the sensor can occur due to the f...

Страница 12: ...ure of the purge gas at 0 5 bar 7 5 psi or lower at all times Calibration HFT has a number of calibration facilities internationally Contact your nearest HFT Distributor who can tell you about your cl...

Страница 13: ...sind momentan im Gange Kontaktieren Sie vorl ufig bitte Ihren rtlichen Verteiler Les autres langues sont actuellement dans le progr s Pour le moment s il vous pla t contacter votre Distributeur local...

Страница 14: ...partenaire en France et en Afrique France Inertage Email clemenceretel huntingdonfusion com Tel 33 6 52 84 28 39 HFT France For further information and support please contact us at Internet www hunti...

Страница 15: ...on Fusion Techniques HFT will not be held responsible for any incorrect use of the product For further warranty information please refer to our terms and conditions All warranties shall not apply to a...

Страница 16: ...1554 836 837 www huntingdonfusion com Email hft huntingdonfusion com E OE Copyright HFT All rights reserved This publication may not be reproduced by any means without the written permission of Huntin...

Отзывы: