background image

 

                                                                                                                                                                                                         

 

Indicator Lights

 

Indicator lights of front power, running

 

No.

 

Indicator Light

 

Functions

 

No.

 

Indicator Light

 

Functions

 

1

 

PWR

 

Red light, indicating 
power 

 

4

 

LED2

 

Yellow light, reserved

 

2

 

RUN

 

Green light, 
indicating running

 

5

 

RX

 

Indicating receiving 
data

 

3

 

LED1

 

Blue light, 
indicating 4G state

 

6

 

TX

 

Indicating transmitting 
data

 

 

 

USB Interface

 

1*OTG for debugging

 

 

 

Ethernet Interface

 

2*independent rear Ethernet interfaces, 10/100Mbps self-adaptive

 

 

 

Serial and CAN Ports

 

4* isolated RS485 interfaces; 1*isolated CAN interface

 

No.

 

Item

 

Function

 

1

 

A1

 

1st RS485 communication

 

2

 

B1

 

3

 

A2

 

2nd RS485 communication

 

4

 

B2

 

5

 

A3

 

3rd RS485 communication

 

6

 

B3

 

7

 

A4

 

4th RS485 communication

 

8

 

B4

 

9

 

CH

 

CAN communication

 

10

 

CL

 

 

 

Button “RST” 

 

1) 

Factory Reset: 

 

Hold on the button”RST(Reset) and supply electricity, it will restore the factory settings.

 

2) 

Network Card Reset: 

 

Press the button”RST(Reset) when the gateway is running, it will restore default IP address.

 

 

 

External Antenna and SIM card

 

External two antenna ports(optional

 

No.

 

Item

 

Function

 

1

 

4G

 

2G/3G/GPRS/4G antenna

 

2

 

GPS

 

GPS antenna

 

3

 

SIM

 

Standard SIM card for 4G

 

 

Содержание ASDU-LS

Страница 1: ...ASDU LS Intelligent Gateway User Manual V1 1 Heyuan Intelligence Technology Co Ltd...

Страница 2: ...served Please read this manual carefully before the product is operated And once you start operating the product you ll be considered to have read this manual and accept all our terms Heyuan shall not...

Страница 3: ...ter 5 Dimension Installation 4 Chapter 6 Key Performance Indicator 5 Chapter 7 Running Configuration Requirement 5 Chapter 8 First Time to Configure 6 Chapter 9 Database Setting 7 Chapter 10 Device Ma...

Страница 4: ...d processor of the integrated automation system to form the middle layer of the automatic system It can communicate upward with each system such as master station and communicate downward with the ter...

Страница 5: ...umption 15W 3 4 Software Configuration Linux 4 1 Embedded various communication protocols Modbus RTU Protocol Modbus TCP IP Protocol DL T 645 Protocol IEC60870 102 103 104 Protocol MQTT Protocol HTTP...

Страница 6: ...ial and CAN Ports 4 isolated RS485 interfaces 1 isolated CAN interface No Item Function 1 A1 1st RS485 communication 2 B1 3 A2 2nd RS485 communication 4 B2 5 A3 3rd RS485 communication 6 B3 7 A4 4th R...

Страница 7: ...y Power Supply DC8 36V connected to the negative pole of power supply connected to the positive pole of power supply Chapter 5 Dimension Installation 5 1 Dimension A Din rail Mounting Dimension Unit m...

Страница 8: ...s working normally Chapter 6 Key Performance Indicator 6 1 Capacity for ASDU LS Intelligent Gateway Item Unit System Capacity Quantity of Connected Smart Devices quantity of simultaneously connected s...

Страница 9: ...192 168 138 1 automatically Use a network cable to connect ETH1 Ethernet interface 1 of the gateway with computer On computer add an IP address192 168 137 XX XX ranges from 2 to 255 and then connect...

Страница 10: ...r and About which respectively refer to the system setting interfaces real time data monitoring interfaces and copyright information of the gateway Tool Bar including save button add record button del...

Страница 11: ...t Configuration In the navigation bar choose Terminal Model Sheet Click buttons in the tool bar to add or delete terminal models and edit the details Screen 9 3 Terminal Model Sheet Configuration Regi...

Страница 12: ...n that is real time data readout data terminal scale 9 3 3 Terminal Energy Register Table Configuration Click buttons in the tool bar to add or delete terminal energy registers and edit the details Sc...

Страница 13: ...nergy registers and edit the details Screen 9 6 Terminal Digital Signal Register Table Configuration Digital Signal Type Single Point Digital Signal Double Point Digital Signal 9 3 5 Terminal Setting...

Страница 14: ...ons of 101 acquisition and forwarding protocol 103 acquisition protocol 104 acquisition and forwarding protocol Modbus acquisition and forwarding protocol 1997 2007 DL 645 protocol and CJ T188 protoco...

Страница 15: ...a 2 Edit Inquiry Frame Screen 9 11 MODBUS RTU Acquisition Protocol Inquiry Frame Editing The Edit Inquiry Frame interface is used to configure the telemetry data energy data and digital signal data a...

Страница 16: ...ype and endianness etc Screen 9 13 Energy Details Editing of MODBUS RTU Acquisition Protocol Inquiry Frame Edit energy names register address data type and endianness etc a 3 Edit Control Frame Screen...

Страница 17: ...15 Details Editing of MODBUS RTU Acquisition Protocol Telecontrol Frame b MODBUS RTU Forwarding Protocol Configuration Screen 9 16 MODBUS RTU Forwarding Protocol Configuration c 1997 DL 645 Protocol C...

Страница 18: ...68 01 02 11 B6 03 16 Address 030000000000H Control Code C 01H Identification Code DI1DI0 B611H Data Length 02H Receive original message 68 03 00 00 00 00 00 68 81 04 44 E9 33 34 EC 16 Message after De...

Страница 19: ...68 61 01 00 00 00 00 68 11 04 00 01 01 02 17 16 Address A0 A5 610100000000H Control Code C 11H Identification Code DI3DI2DI1DI0 02010100H Data Length 04H Send original message 68 61 01 00 00 00 00 68...

Страница 20: ...007 DL 645 Protocol Configuration e 101 Acquisition Protocol Configuration Screen 9 21 101 Acquisition Protocol Configuration f 101 Forwarding Protocol Configuration Screen 9 22 101 Forwarding Protoco...

Страница 21: ...isition Protocol Configuration Screen 9 23 103 Acquisition Protocol Configuration h 104 Acquisition Protocol Configuration Screen 9 24 104 Acquisition Protocol Configuration i 104 Forwarding Protocol...

Страница 22: ...19 Screen 9 25 104 Forwarding Protocol Configuration j CJ T188 Water Meter Protocol Configuration Screen 9 26 CJ T188 Water Meter Protocol Configuration...

Страница 23: ...ater Meter Protocol Details Configuration 9 4 2Communication Channel Configuration Screen 9 28 Communication Interface Details Configuration Configure the information of serial ports 9 4 3Communicatio...

Страница 24: ...n of connected terminals 9 4 4Front end Communication Sheet The sheets of front end communication telemetry energy digital signal setting value telecontrol will be automatically generated based on the...

Страница 25: ...ration 9 5 2Forwarding Channel Configuration Screen 9 31 Forwarding Channel Configuration 9 5 3 Forwarding Terminal Configuration In the communication terminal sheet the communication interface is the...

Страница 26: ...nt 10 1 Communication Configuration 10 1 1 Local Communication Parameter Configuration The local communication parameter configuration is used for debugging when the gateway is directly connected to t...

Страница 27: ...U LS equipped with 4G function On interface Device Management choose Cloud Communication Parameter Configuration and fill cloud service IP address and gateway details Screen 10 2 Cloud Communication P...

Страница 28: ...Configuration and Program Upgrading Package Please choose the corresponding file type and path and then click send file 10 4 File Calling Screen 10 5 Calling File The Database File Configuration File...

Страница 29: ...FDT C1 2 DZS100 JFDT C1 2 DZS100 2 DZS100 JFDT C1 2 DZS100 2 DZS100 2 DZS100 2 DZS100 JFDT C1 JFDT C1 JFDT C1 DZS300 2 DZS100 JFDT C1 DZS300 ASDU001 ASDU002 ASDU006 ASDU005 AL20 AL21 AL23 AL24 AL25 AL...

Страница 30: ...e cost according to actual situation will be charged Service Guarantee 1 Product technical consulting and quality complaints will be replied within 12 hours 2 Solutions for quality complaints will be...

Отзывы: