7. Maintenance / fault finding
Cleaning the filter
The filter should be cleaned every 2 weeks.
Remove the filter element from the device and clean the filter with warm water. Clean the machine with a damp
cloth.
Attention! Never spray the appliance directly with water or use chemicals for cleaning.
Warning: Danger of electric shock
The unit must be disconnected from the mains before any maintenance work is carried out on it. Electrical
components must not be cleaned with a water hose or pressure washer, as water could penetrate the electrical
components and cause an electric shock.
When dismantling components, please turn the screws by hand to avoid damage to the threads!
Warning: The refrigeration system is filled with the highly flammable gas R290.
Maintenance and repair work on the refrigeration system must be carried out by an authorized specialist
under the necessary safety precautions.