Configuration and Operations
LD900 Installation and Oper ations M anual
47
If selecting
NMEA
, a choice of
GGA
,
GLL
,
VTG
,
ZDA
,
GST
,
GSA
,
GSV
,
GRS
and
RMC
will be shown, followed
by a request to pick an NMEA output rate of
1
(default),
2
,
5
,
10
or
20
Hz. If heading is licensed and
HDT
will also be shown and additionally if INS is licensed
PASHR
will be shown.
Once configured the user will be returned to the
Configuration > Ports
page.
4.6.4.3
Configuration > Ports > P (1 to 7)
If the
system is interfaced seven Moxa serial port expansion unit ports and will be
available. These will be named P1 - P7:
To select a specific port for input or output use the arrow buttons and tick to select the required
P#
port. A
P#
Settings
page will then be displayed. With
Baud Rate
highlighted use tick to
Edit
the baud rate if required.
LD900 P1-7 are set to a baud rate of 115200 by default but support a baud rate between 1200 to 460800. Use
the Arrow keys followed by tick to select the required baud rate.
Once returned to the
P# Settings
page, use the arrow buttons to highlight
Additional Settings
and tick to
Edit
.
Use the up and down arrow buttons to navigate through the options and tick to
Edit
as required:
P Port
Moxa Port
P1
1
P2
2
P3
3
P4
4
P5
5
P6
6
P7
7