Range noise* (1 sigma; Kodak Grey Card (Albedo 90%)):
Distance
30 kHz
8 kHz
1000 Hz
1 Hz
10 m
2.0 mm
1.0 mm
0.6 mm
0.4 mm
25 m
2.2 mm
1.2 mm
0.8 mm
0.5 mm
50 m
3.0 mm
1.5 mm
1.0 mm
0.6 mm
100 m
-
5.0 mm
2.0 mm
0.8 mm
200 m
-
-
6.0 mm
1.8 mm
Object in shade, sky overcast. Beam interruptions, severe heat shimmer and
moving objects within the beam path can result in deviations of the specified
range noise and accuracy.
*
Range noise describes the standard deviation of the scan points
residuals to the modelled surface:
•
Plane surface target
•
Perpendicular orientation of the plane target to the measure-
ment direction
•
Modelled plane best fitted into the point cloud
The absolute position accuracy of a modelled surface is similar to an RL single
measurement:
Standard measuring
Standard deviation
ISO 17123-4
0 m - 500 m
2 mm + 2 ppm
>500 m
4 mm + 2 ppm
Type
Scan area
Resolution
Duration
Full dome scan
400 gon x 155 gon 50 mm @ 15 m
12 min
Band scan
400 gon x 50 gon
12.5 mm @ 50 m
45 min
7.7
PowerSearch (PS)
Reflector
Range
[m]
[ft]
Standard prism
(GPR1)
300
1000
360° prism
(GRZ4, GRZ122)
300*
1000*
360° mini prism
(GRZ101)
Not recommended
Mini prism
(GMP101)
100
330
Measurements at the vertical limits of the fan or under unfavourable atmo-
spheric conditions may reduce the maximum range. (*optimally aligned to the
instrument)
Shortest measuring distance:
1.5 m
Accuracy
Scan duration
Range
Technical Data
73