Table 10 Encryption SAN Switch and FRU LEDs (continued)
Recommended action
Status of hardware
LED color
LED name
•
Check the power cable
connection.
•
The power cable is
disconnected.
•
Replace the power supply FRU.
•
The power supply FRU has
failed.
NOTE:
When the switch is first
powered on, the power supply
status LED shows amber until
POST has completed.
Do one of the following:
Indicates one of the following:
No light
Fan status
•
Verify that the fan FRU is seated
correctly.
•
Fan FRU is not seated
correctly.
•
•
Fan FRU is not receiving
power.
Verify that the switch is powered
on.
No action required.
Fan assembly is operating
normally.
Steady green
Do one of the following:
Indicates one of the following:
Steady amber (for
more than 5 seconds)
•
Verify that the fan FRU is seated
correctly.
•
Fan FRU is not seated
correctly.
•
One or more of the fans in the
fan FRU has failed.
•
Verify that the fan FRU is enabled
(use the
fanenable
command).
•
The fan FRU was disabled by
the user.
•
Replace the fan FRU.
NOTE:
When the switch is first
powered on, the fan status LED
shows amber until POST has
completed.
Port side LED activity for the FCoE Converged Network Switch
shows the port side of the FCoE Converged Network Switch. There are two
port status LEDs above each of the top row of ports. The left LED is for the top port, and the right
LED is for the bottom port. See
for the locations of the GbE and FC ports.
Figure 31 Port side LEDs on the FCoE Converged Network Switch
4. Ethernet link LED
1. System power LED
5. CEE port status LED (port 0)
2. System status LED
6. CEE port status LED (port 4)
3. Ethernet speed LED
describes the port side LEDs and the recommended actions.
Port side LED activity for the FCoE Converged Network Switch
57