Description
Chassis
Fan configuration
Number of drives
supported by the
server
Maximum inlet
ambient
temperature
(24 SFF or 16
SFF + 8 NVMe
backplane)
Not supported
Apollo r2800
Gen10 Chassis
(24 SFF
backplane with
SAS expander)
Redundant and
nonredundant
0 to 24 drives
Not supported
Apollo r2800
Gen10 Chassis
(16 NVMe
backplane)
Redundant and
nonredundant
0 to 8 drives
Not supported
Not supported
Nonredundant
Not supported
Redundant
Optical cable: 22°C
(71.6°F)
Copper cable: 22°C
(71.6°F)
The drive capacity must be less than 10 TB.
The drive capacity must be greater than or equal to 10 TB.
If the component is installed in server 1, and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks
must be installed in drive bays 1-2 and 1-10. Similarly, if the component is installed in server 3, and the server is
installed in the Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and 3-10. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2200 Gen10 Chassis, bezel blanks
must be installed in drive bays 1-9, 1-10 and 1-11. If the component is installed in server 3 and the server is installed
in the Apollo r2200 Gen10 Chassis, bezel blanks must be installed in drive bays 3-9, 3-10 and 3-11. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2600 Gen10 Chassis, bezel blanks
must be installed in drive bays 1-9 to 1-14. If the component is installed in server 3 and the server is installed in the
Apollo r2600 Gen10 Chassis, bezel blanks must be installed in drive bays 3-9 to 3-14. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, the removable
blanks must be installed in drive bays 2-1 to 2-4. If the component is installed in server 3 and the server is installed in
the Apollo r2800 Gen10 Chassis, the removable blanks must be installed in drive bays 4-1 to 4-4. For more
information, see
Installing drive blanks and thermal bezel blanks for components with thermal limitations
on
page 23.
If the component is installed in server 1 and the server is installed in the Apollo r2800 Gen10 Chassis, bezel blanks
must be installed in drive bays 1-3, 1-4, 2-1, 2-2, 2-3, and 2-4. If the component is installed in server 3 and the server
is installed in the Apollo r2800 Gen10 Chassis, bezel blanks must be installed in drive bays 3-3, 3-4, 4-1, 4-2, 4-3 and
4-4. For more information, see
Installing drive blanks and thermal bezel blanks for components with thermal
on page 23.
Specifications
149