3.
Install all components removed from the failed system board.
Be sure to install the DIMMs in the same DIMM slots as the failed system board.
4.
Do the following:
• Install the primary PCIe riser cage.
• Install the primary PCIe riser blank.
5.
Do the following:
• Install the secondary PCIe riser cage.
• Install the secondary PCIe riser blank.
6.
Install the bayonet board.
7.
Install the server from the chassis.
8.
Connect all peripheral cables to the server.
9.
10. Access System Utilities and:
•
Re-enter the server serial number and product ID.
• If the server is using Intel Xeon Gold 6244 processors,
select an advanced fan cooling method.
11. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to ensure that
the latest drivers are being used.
Re-entering the server serial number and product ID and selecting an advanced fan
cooling method
After you replace the system board, the server serial number and the product ID must be configured:
66
Removal and replacement procedures