7.
Connect each power cord to the power source.
on page 42.
9. Enable the increased cooling function
on page 42.
The installation is complete.
Enable the increased cooling function
The server generates more heat when it is installed in a rack. To maintain proper cooling, increase the fan
speed.
Procedure
1.
From the
System Utilities
screen, select
System Configuration
>
BIOS/Platform Configuration
(RBSU)
>
Advanced Options
>
Fan and Thermal Options
>
Thermal Configuration
.
2.
Select
Increased Cooling
3.
Save your setting.
Power up the server
To power up the server, use one of the following methods:
• Press the Power On/Standby button.
• Use the virtual power button through iLO.
Removing and replacing a drive blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all
bays are populated with either a component or a blank.
42
Removal and replacement procedures