Specifications
Environmental specifications
Specification
Value
—
Operating
10°C to 35°C (41°F to 95°F)
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
Nonoperating
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft)
• Redundant fans are required when the ambient temperature reaches 35°C (95°F) to 40°C (104°F).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website (
http://www.hpe.com/servers/ASHRAE
).
Mechanical specifications
Dimension (with feet/bezel)
Value
Height
44.00 cm (17.32 in)
Depth
48.05 cm (18.92 in)
Width
19.50 cm (7.68 in)
Weight (approximate)
Minimum (one drive, power supply, and processor
installed)
13.5 kg (29.82 lb)
Maximum (all drives, power supplies, and processors
installed)
25.0 kg (55.00 lb)
Specifications
117
Содержание HPE ProLiant ML110 Gen10
Страница 23: ...Customer self repair 23...
Страница 24: ...24 Customer self repair...
Страница 25: ...Customer self repair 25...
Страница 109: ...Storage controller backup power cabling Energy pack cabling Cabling 109...
Страница 112: ...iLO Service Port cabling Fan cabling Default system fan cabling 112 Cabling...