The Aruba 7024 Mobility Controller requires a minimum of 7 TELs to be applied as follows:
To Detect Opening the Chassis Lid Top
•
Spanning the front bezel and the chassis lid, as shown in Figures 12 and 13 (Label 1).
To Detect Opening the Chassis Lid Bottom
•
Spanning the bottom and the chassis lid, as shown in Figure 13 (Labels 4, 5, 6 and 7).
To Detect Access to Restricted Ports
•
One label (label 3) spanning the RJ-45 serial port and one spanning the mini-USB port (label 2) as shown in
Figure 14 and 15 (labels 2 & 3). Press down on this label to ensure that it adheres to a sufficient area of the front
bezel. The RJ-45 port is raised relative to the bezel so there will be some air gap under the label in this area.
However, the air gap should not be larger than 2-3mm.
Figure 12
Required TELs for the Aruba 7024 Mobility Controller - Front
Figure 13 Required TELs for the Aruba 7024 Mobility Controller – Top
Figure 14 Required TELs for the Aruba 7024 Mobility Controller – Rear
Aruba 7XXX Series Controllers FIPS 140-2 Level 2 Security Policy
|37