7. Reset on first start-up /
Manual reset
During the first start-up, there is a compulsory reset in order to be
able to commission the product.
The reset puts all columns on the same level. This ensures that
the table top is moved parallel to the basic level. In addition, the
control stores the connected components in the standard version.
If the actual table top position no longer matches the displayed
table top position or an already configured control unit is used
with another identical electrical height-adjustable workstation,
you have to perform an end position adjustment of the lowest
table top position.
WARNING!
Collision detection (ISP)
is
not active
in any reset
cycle or during end position calibration. Please realise
that you could get crushed!
8. Returning control unit to factory settings
(S0 menu)
This function allows you to return the control unit to factory set-
tings.
To be able to use the control unit again after changing a lifting
column‘s configuration in this way, proceed as follows:
1. Press the
desk top down
button.
Keep the
desk top down
button pressed
until the desk top has reached the lowest
position (programmed end position).
2. Press the
desk top down
button again
and continue to keep it pressed. After
approx. 5 seconds the desk top will
continue to move down until the bottom
most desk top position is reached.
3. Release the
desk top down
button. The
electrically height adjustable workstation
can be used in the normal way again.
Simultaneously press
memory position
button 1, memory position button 2
and
the
desk top up
button.
Keep this button combination pressed for
approx. 3 seconds.
The display shows
S 1.
Now release the buttons.
Keep pressing the desk top up button until
the display shows
S 0
.
The display shows
S 0
.
Press the
save button
.
The control unit is returned to factory
settings. The control unit is now in the
same state as it was when you put it into
operation for the first time.
2
1
2
1
2
1
SAVE
Handset display shows error code E70.
1. Unplug the control unit‘s power supply
and wait at least 5 seconds.
2. Plug the control unit‘s power supply back
in again.
3. Carry out a manual reset (see section 7).