16
Check the following list before turning the transmitter
on.
• Be sure there is a fully charged battery pack in
the transmitter.
• Push in the E-Stop button.
• Be sure the motion pushbuttons are in their OFF
(neutral) positions.
TEST THE SYSTEM
• Remove the cover from the receiver.
• Position yourself in front of the receiver so that all
LEDs and connections are visible.
LED Designations and Layout for all RX
WARNING:
FAILURE TO FOLLOW
INSTRUCTIONS could result in personal
injury and/or damage to equipment. Read and
understand the safety instructions in all
manuals provided.
Testing or service must be performed by
authorized personnel only.
There must be no load on the crane/machine.
Clear the crane/machine operating area of
obstructions.
REL6-RX
F1
F2
Emergency
Stop
K1
K2
K3
K4
K5
K6
K7
K8
K15
K16
K17
K18
K19
K20
1
2 3 4 5 6 7 8
1
2 3 4 5 6 7 8
1
2 3 4 5 6
1 2 3 4 5 6 7
8
1
2 3 4 5 6 7 8
1
2 3 4 5 6
9 10 11 12
9 10
1. CPU Yellow LED
2. Transmission Green LED
3. E-stop Fault Red LED
4. Telegram Type Red LED
5. E-stop Relay Activated Red LED
6. Output Relays K1 - K20 Activated
Red LEDs
5
6
2
3
1
4