USE
R’S MANUAL |
ERGO-S
20
8.
T
roubleshooting
If your ERGO-S does not operate after normal start-up, follow the recommended troubleshooting sequence to help isolate the cause and
determine corrective action. If you need more information, contact your nearest Hetronic dealer.
PROBLEM
PROBABLE CAUSE
CORRECTION
Transmitter wo
n’t start
Incorrect Access code (if
enabled)
Enter correct access code
Battery fully discharged
Replace with fully charged battery if needed
The transmitter is turned
on, but does not transmit
(Power LED not flashing)
Battery is discharged
Replace battery with a fully charged battery
Component failure
Contact your supervisor or nearest Hetronic
Service Centre
Transmitter is transmitting
(Power LED flashing), but
machine will not respond
No power to the receiver
Check the diagnostic LEDs in the receiver to be
sure power is applied. Ensure that the system is
properly grounded
Transmitter/receiver frequency
channels do not match
Follow instructions under “Setting Frequency
and channels” or contact your supervisor
Transmitter out of range
Take the transmitter back into the range of the
receiver, press START
Receiver power off
Turn on power to receiver
Blown fuse in receiver
Check all fuses and replace if needed
STOP failure in receiver. Red
STOP LED on PC board is
illuminated
Contact your supervisor
All machine motions
operate intermittently
Receiver antenna connection
is loose or missing
Tighten or replace antenna
External antenna (if used) has
loose connection, poor
grounding or interference
Tighten antenna and ground connection.
Contact Hetronic or your Dealer for more
information
Connector inside receiver is
loose
Check all connectors, reseat if needed
Another frequency may be
interfering with the system
Contact your supervisor
Table 4. Troubleshooting tips