1.11 operational problems

The  chimney  must  be  swept  at  least  once  a 
year, we recommend the use of a NACS (natio-
nal  association  of  chimney  sweeps)  registered 
chimney sweep.

In the event of smoke or malodorous fumes are
being  produced,  you  must  first  check  to  see 
whether the chimney is blocked.

The chimney must, of course, always provide the 
minimum draft necessary to ensure that it is pos-
sible to regulate the fire. Please note, how-ever, 
that  chimney  draft  is  dependent  on  the  weather 
conditions. In high winds, the draft can become 
so powerful that it may be necessary to fit a dam-
per in the flue gas pipe to regulate the draft.

When  cleaning  the  chimney,  soot  and  other 
deposits  may  come  to  fall  on  the  baffle  plate, 
remove  and  clean  it.  In  cases  where  the  wood 
burns too quickly, this may be due to excessive 
chimney draft. You should also check to make 
sure that the door seal and ash pan seal is intact 
and  correctly  fitting.  If  the  stove  it  generating 
too little heat, this may be because you are firing 
with wet wood. In this case, much of the heat-
ing energy is used to dry the wood, resulting in 
poor efficiency, potentially damaging the vermi-
culite and an increased risk of soot deposits in 
the chimney.

1.12 Chimney fire

In case of a chimney fire, which often results from 
incorrect  operation/maintenance  or  prolonged 
use  of  damp  wood,  close  the  door  and  the  air 
supply completely, to help slow/smother the fire.

Call  the  fire  department.  The  stove  and  chimi-
ney must be inspected before use again.

1.13 Maintenance

The surface of the stove is treated with a heat-
resistant  paint.  The  stove  should  be  cleaned 
with a damp cloth.
Any damage to the surface in the form of chips 
or  scratches  can  be  repaired  using  touch-up 
paint, which is available in spray can

1.14 Cleaning the glass

Incorrect  firing,  for  example  using  wet  wood, 
can result in the viewing window becoming co-
vered in soot. This soot can be easily and effec-
tively removed by using proprietary stove glass 
cleaner.

  

1

  

2

  

3

  

4

  

5

1.15 Cleaning the oven

Remove  and  clean  baking  racks  and  rails.  The 
oven should be cleaned with mild oven cleaner. 
See fig. 1-5.

Содержание Scan-Line 900 SCA

Страница 1: ...n instrUCtions Danish DesiGn Danish QUality Danish ProDUCtion www heta dk en sCan line 900 series sCan line 900 sCa series Scan line 900 SCA is exempt for use in smoke control areas when burning dry w...

Страница 2: ...05 2022 0037 1545 Version 2 3 Printed in Denmark Subject to printing errors and changes operating instructions Contents Before installation 3 4 1 Operating instructions 5 1 1 Before using 5 1 2 First...

Страница 3: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 4: ...t 300 ELAB 2276 EN SN No 07 2017 Scan Line 1000 Br ndsel Tr Ovnen er godkendt til intermitterende brug F lg fabrikantens brugervejledning Ovnen kan anvendes p r ggassamleledning Afstand til br ndbart...

Страница 5: ...unts of smoke and un burnt hydrocarbons The appliances will only be considered as an exempt appliance if this stop is in place Before lighting it is very important that the vent in the baking oven is...

Страница 6: ...y of firewood kg Scan Line 900 series 31 1 52 Scan Line 900 Side windows series 40 1 71 The door must be closed during operation The ashtray must be secure and must not be able to move after being set...

Страница 7: ...ow the stove to burn as it should The glass can soot requires cleaning of the chimney more often smoke can escape out when the door is open and it gives poor fuel ef ficiency Leading to unnecessary po...

Страница 8: ...imney fires If the wood is damp and inadequately seasoned a large proportion of the energy in the fuel will be used to vaporize the water and this will all disap pear up the chimney Thus it is importa...

Страница 9: ...oo little heat this may be because you are firing with wet wood In this case much of the heat ing energy is used to dry the wood resulting in poor efficiency potentially damaging the vermi culite and...

Страница 10: ...on Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe if necessary The door or ash pan drawer...

Страница 11: ...ects 1 year on paint adhesion defects from purchase date from Heta and a 3 months total warranty for seals vermiculite and glass from the date of sale from the dealer Claims concerning stoves older th...

Страница 12: ...aphite spray Before using graphite spray you should cover the exposed surfaces so that lubricants are applied only to the moving parts Always test the graphite spray on a hidden surface to make sure t...

Страница 13: ...5 6 1 2 3 4 4 5 6 13 1 20 scan line 900 series Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Rep...

Страница 14: ...side windows series Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks...

Страница 15: ...ine 900 stone top 155 kg Scan Line 900 B steel 177 kg Scan Line 900 B stone 243 kg Scan Line 900 B stone top 186 kg Scan Line 900 S steel 214 kg Scan Line 900 S stone 298 kg Scan Line 900 S stone top...

Страница 16: ...261 Vermiculite side right 1 3 0023 006465 Vermiculite side left 1 4 0023 011495 Baffle 1 5 0023 012044 Baffle small 1 6 0023 012060 Vermiculite rear top 1 7 0023 012061 Vermiculite rear right 1 8 002...

Страница 17: ...Side windows 2 6 0023 006110 Baffle two part right 1 7 0023 006467 Vermiculite front left 1 8 0023 012056 Vermiculite smal side left 1 9 0023 012057 Baffle two part left 1 10 0030 0201 Grate 195 mm 1...

Страница 18: ...rivet 1 5 0021 006404 Glass 1 6 0023 012405 0023 3008 Glass gasket 12 L 1 84 m 1 7 0023 012407 0023 3010 Textile glass 6 mm with adhesive black L 1 3 m 1 8 0023 012408 0023 3010 Textile glass 6 mm wi...

Страница 19: ...008 Glass gasket 12 soft L 1 84 m 1 7 0023 020340 0023 3010 Textile glass 6 mm with adhesive L 1 75 m 1 8 0023 020341 0023 3013 Glass band 3x8 mm with adhesive L 0 42 m 1 9 0030 008095 Stove door glas...

Страница 20: ...008 1002 Set screw 2 3 0008 018935 Round head rivet steel 2 4 0021 020355 Glass 1 5 0023 012408 0023 3010 Glass gasket Textile glass 6 mm with adhesive black L 0 36 m 2 6 0030 019579 Baking oven door...

Страница 21: ...1 Distance requirements 22 2 2 Floor 22 2 3 Chimney connection 22 2 4 Combustion air and ventilation 22 2 5 Stovedrawings measurments 23 2 6 Assembling the thermal stones 25 2 7 Connecting direct air...

Страница 22: ...support the weight of the stove and a top mounted steel chimney In front of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The...

Страница 23: ...nt formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into the open air please note that the grille must be fitted with suitable wind protect...

Страница 24: ...p H 1491 1511 Scan Line 900 B series H 514 162 100 73 40 443 1457 217 1060 1330 181 421 Center for fresh air Casted top Stone top H 1491 1511 24 Scan Line 900 Side windows series Scan Line 900 Stone S...

Страница 25: ...1 1511 25 H 514 443 40 100 1457 73 162 217 1060 1330 181 421 H 514 217 1060 181 421 162 73 443 40 100 1168 Scan Line 900 S Side windows series Scan Line 900 B Side windows series Center for fresh air...

Страница 26: ...26 1 1 3 1 2 1 2 4 0023 022143 0023 022142 5 6 2 2 9 7 8...

Страница 27: ...lexi pipe to the floor Flexi pipe back outlet Direct air supply The dimensions of the direct air supply pipe may not be less than 100 mm the draught in the flue depends on this air for optimal combu s...

Страница 28: ...gian fire wall Distance to firewall with 108 mm brick A Rear the sto ve insulated uninsulated flue pipe B At the side C Over oven D To furnitures E Corner distance F Rear the stove uninsulated flue pi...

Страница 29: ...1 2 4 1 3 2 4 3 29 2 10 Changing to a back outlet steel model with casted top 2 11 Door stop location 1 2...

Страница 30: ...on 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Re gulatory Reform Scotland Act 2014 In Wales an...

Страница 31: ...iciency NCV as received Useful efficiency at nominal heat output th nom 83 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output elmax kW At minimum...

Страница 32: ...tput Pmin Useful efficiency NCV as received Useful efficiency at nominal heat output th nom 82 Useful efficiency at minimum heat output th min Auxiliary electricity consumption At nominal heat output...

Отзывы: