Installation and Operating Instructions for Heta SL800 Aqua stove Pevex1018/AH/ver1:Jan 2013

The Clean Air Act 1993 and Smoke 

Control Areas

Under the Clean Air Act local autho-

rities may declare the whole or part 

of the district of the authority to be a 

smoke control area. It is an offence to 

emit smoke from a chimney of a buil-

ding, from a furnace or from any fixed 

boiler if located in a designated smoke 

control area. It is also an offence to 

acquire an ”unauthorised fuel” for use 

within a smoke control area unless 

it is used in an ”exempt” appliance 

(”exempted” from the controls which 

generally apply in the smoke control 

area).

The Secretary of State for Environ-

ment, Food and Rural Affairs has 

powers under the Act to authorise 

smokeless fuels or exempt applian-

ces for use in smoke control areas in 

England. In Scotland and Wales this 

power rests with Ministers in the de-

volved administrations for those coun-

tries. Separate legislation, the Clean 

Appendix A

Air (Northern Ireland) Order 1981, ap-

plies in Northern Ireland. Therefore it 

is a requirement that fuels burnt or ob-

tained for use in smoke control areas 

have been ”authorised” in Regulations 

and that appliances used to burn solid 

fuel in those areas (other than ”aut-

horised” fuels) have been exempted 

by an Order made and signed by the 

Secretary of State or Minister in the 

devolved administrations.

The Scan-Line 800 Aqua and Aqua 

low have been recommended as 

suitable for use in smoke control areas 

when burning dry wood logs.

Further information on the require-

ments of the Clean Air Act can be 

found here : http://smokecontrol.

defra.gov.uk/

Your local authority is responsible for 

implementing the Clean Air Act 1993 

including designation and supervision 

of smoke control areas and you can 

contact them for details of Clean Air 

Act requirements.

21-05-2013  0037-1385

Содержание SCAN-LINE 800 AQUA

Страница 1: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 www heta dk SCAN LINE 800 AQUA APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS OPERATING INSTRUCTIONS GB...

Страница 2: ...the floor area must match national and local regulations The chimney connection The chimney opening must follow national and local regulations Howe ver the area of the opening should of specifications...

Страница 3: ...e weight of the chimney excessive weight may cause damage on or noise from the stove Draft conditions Poor draft may result in smoke being emitted from the stove when the door is opened The minimum ch...

Страница 4: ...me correct firing prevents environ mental damage in the form of smoke and emmissions and also reduces the risk of chimney fires If the wood is wet and inadequately seasoned a large proportion of the e...

Страница 5: ...top position fig 1 Reduce combu stion airflow gradually by lowering the handle When the handle is in the lowest position fig 2 combustion airflow is completely closed Fig 1 Fig 2 Open Closed The SL80...

Страница 6: ...go out a red hot ember bed will be left and further wood can be added 6 Place 2 3 logs on the ash bed ensu ring that the wood is not stacked too closely and with the adjust the side airslider to fully...

Страница 7: ...air controls or dampers left open except as directed in the instructions Refuelling A fresh supply of fuel should nor mally be added while there is still a good layer of hot embers Spread the embers...

Страница 8: ...ary and se condary air in these instructions we call this combustion air The stove provides excellent heating efficiency and the window is easy to maintain as the secondary air flushes the surface of...

Страница 9: ...ith wet wood In this case much of the heating energy is used to dry the wood resulting in poor heating eco nomics and an increased risk of soot deposits in the chimney OPERATIONAL PROBLEMS MAINTENANCE...

Страница 10: ...the dealer Therefo re the stoves are guaranteed against defects in manufacturing FOR FIVE YEARS This guarantee does not cover Wea ring parts fragile parts such as The fire proof bricks in the combu s...

Страница 11: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 Connection of external air flow fresh air through the floor on Scan Line 800 Aqua When connection external air flow use a 100 air conduit for in...

Страница 12: ...Operating Instructions for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 4 5 6 7 Emptying the ash pan fig 4 7 Cleaning after sweeping the chimney and replacing the stones Fig 8 14 Scan Line 800 Aqu...

Страница 13: ...etween the cooling pipes lies as as sembled on the picture as when you receive it from Heta otherwise it will result in great loss of efficiency and raise the temperature of the chimney Tip the top pl...

Страница 14: ...AH ver1 Jan 2013 Connection water to Scan Line 800 Aqua Fig 20 Bleed screw SYR Temperature valve pkt 5 Forward motion warm 1 2 RG point 4 12 mm copper pipe for water connection point 1 Return cold 1 2...

Страница 15: ...sure The SYR valve point 5 is an extra safety device which opens by a tem perature over 95 in the boiler Connect cold water pressure on maxi mum 15 on the water connection point 1 make sure that your...

Страница 16: ...d In Scotland and Wales this power rests with Ministers in the de volved administrations for those coun tries Separate legislation the Clean Appendix A Air Northern Ireland Order 1981 ap plies in Nort...

Отзывы: