background image

energy source, you save the environment about 
1.3 kg CO

2

 every time you have used 1 kg nor-

mal wood.

Chimney fires

In the event of a chimney fire – which often re-
sults  from  incorrect  operation  or  protracted  fi-
ring with moist wood – close the door and shut 
off the secondary/start-up air supply to smother 
the fire. Call the fire department.

airflow regulation

The  combustion  air  flow  is  controlled  by  the 
handle at the top right, as shown on fig. 1. 
The combustion air flow is fully open when the 
handle is as far back as possible. Combustion 
air  is  gradually  reduced  by  moving  the  handle 
forward, and is completely shut off when it rea-
ches the front position.

lighting the stove

Place two pieces of wood on the bottom. Stack 
kindling on top in layers with air between. Set-
ting fire starter (bag, brick, paraffin) on the top, 
now you are ready to light the fuel. The flames 
must work from the top down. 

The use of lighter fluid, oils or 
any liquid fuels is strictly forbid-
den from use in a wood stove.

Fully  open  the  combustion  air  and  leave  the 
door ajar (about 1 cm open).

Once the fire is established and the chimney is 
hot  (after  about  3-5  minutes)  closed  door  and 
regulate the air into operating position. We re-
commend, all of the first fuel is burned with the 
combustion  air  fully  open  in  the  operating  po-
sition. This ensures the stove and chimney are 
thoroughly heated.

 

     

Startup/Lighting

 

     

Scan the code and select a  

 

     

 

language.

adding fuel

A fresh supply of fuel should normally be added 
while  there  is  still  a  good  layer  of  hot  embers. 
Spread  the  embers  over  the  base  grate,  most 
towards the front of the stove. Lay a single layer 
of wood fuel corresponding to about 1.5 kg over 
the  embers,  at  right  angles  to  the  stove  door. 
Turn handle into top position (max.  Combusti-
on-  airflow).  Keep  door  ajar  if  necessary.  (The 
door should not be left open but fuel will ignite 
more quickly while the door is ajar.) The wood 
should  ignite  within  a  very  short  time  (usually 
1-3 minutes). If the door is ajar, close it as soon 
as  the  fuel  is  ignited.  When  the  flames  spread 
across  the  fuel  stack,  adjust  the  combustion 
airflow to the required level. Nominal operation 
6 kW corresponds to 80% combustion airflow. 
When adding fuel, make sure that the fuel is not 
too  tightly  packed,  as  this  will  lead  to  poorer 
combustion and fuel inefficiency.
Never fill firewood over the stove’s max. fill line. 
See fig. 3.

reduced burning

The  stove  is  well  suited  to  intermittent  use.  If 
you wish to operate the stove with reduced out-
put,  simply  insert  smaller  volumes  of  wood  at 
each firing, and apply a lower airflow. However, 
remember  that  the  secondary  combustion  air 
supply  must  never  be  shut  off  completely  du-
ring firing. It is important to keep a good bed of 

2

1

Open

Closed

3

Max. fill line.

Содержание SCAN-LINE 80

Страница 1: ...tinG anD installation instrUCtions Danish design Danish Quality Danish Production www heta dk EN Scan line 80 and 80 XL APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED...

Страница 2: ...0 077 R ggas temperatur 204o C St v 10 mg Nm3 Virkningsgrad 86 NOx 80 mg Nm3 OGC 76 mgC Nm3 DOP Scan Line 1000 2017 8057 0000 DK Congratulations on your new stove We are sure that you will be happy w...

Страница 3: ...low national and local regulations However the area of the ope ning should never be less than 175 cm2 which corresponds to a diameter of 150 mm If a dam per is fitted in the flue gas pipe there must a...

Страница 4: ...d pressure impregna ted wood or chipboard as these materials can emit poisonous fumes and smoke Correct fi ring using well seasoned wood provides opti mal heat output and maximum economy At the same t...

Страница 5: ...ully open in the operating po sition This ensures the stove and chimney are thoroughly heated Startup Lighting Scan the code and select a language Adding fuel A fresh supply of fuel should normally be...

Страница 6: ...es of gas and this gas can explode if the intake of primary and se condary air is insufficient It is an advantage always to leave some ash lying in the bottom of the combstion chamber Take care when e...

Страница 7: ...r example using wet wood can result in the viewing window becoming co vered in soot This soot can be easily and effec tively removed by using proprietary stove glass cleaner Cleaning and repairing soa...

Страница 8: ...mm hose is recommended available from Heta which can handle tempe ratures up to 200 C Fig 1 illustrates the two options downwards or backwards 2 3 4 5 Emptying the ash pan The ash pan is located behi...

Страница 9: ...ea to remove the two heat storage stones before making the change After swapping the flue outlet connector and blanking plate the stove is ready for rear flue connection Swap the flue outlet connec to...

Страница 10: ...he top in line with the installation instructions for soapstone ceramic Scan Line 80 and 80XL stoves on page 11 19 The dimensions on the drawing fig 1 have been measured from the bottom edge of the ba...

Страница 11: ...est to change this before installing the cladding See the operating instructions at page 9 Before commencing installation ensure that the stove is level Varenr soapstone Antal SL 80 Antal SL 80XL A 00...

Страница 12: ...8 14 F 0023 2369 2 G 0023 2370 2 2 E E E E E E E C D Side 23 27 11 2015 G G A F F CLADDING TYPE AND PRODUCT NUMBERS Mounting of radiant plates Scan Line 80 with ceramic 1 2 4 3 IMPORTANT Before using...

Страница 13: ...he mounting pegs 47 mm from the top of the cladding stone in the large circular holes in the keyholes Let the stone slide down so the pegs are at the bottom of the keyholes When installing soapstone p...

Страница 14: ...14...

Страница 15: ...however you want as the same type of clad ding stone panels are used on the opposite side of the stove D C E E E E E E E Fourteen cladding stone panels E are needed for the Scan Line 80 XL These pane...

Страница 16: ...s may need to be adjusted to be level with the cladding stones on the sides of the stove Do this by loosening the four screws two on each side use a 4 mm hex key Start by loosening the bottom two scre...

Страница 17: ...the cladding stones have been installed Cover plate 4027 0039 is not used if the rear flue outlet is being used Cover plate 4027 0037 is not used if the out side air connection is being used If there...

Страница 18: ...mastones The other two can be purchased as optional extras Remove the transportation bracket before using the stove or installing additional ther mastones The Scan Line 80 has no therma stones Screw t...

Страница 19: ...flue outlet is being used remove the centre cover plate using pliers X Y Z INSTALLATION OF CERAMIC TOP AND CONVECTION TOP PANEL Install the convection top panel as follows 1 push x into the slot y in...

Страница 20: ...s used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and sig ned by the Secretary of State or Minister in the devolved administrations The Scan Line...

Отзывы: