and exposed parts of the body.
The relative humidity of the environment should not be more than
85%, and there should be no corrosive gas in the air;
In case it is necessary to see the light tube, use ordinary glass
(glasses) or transparent plastic sheet as a protective mask;
Do not modify by yourself, do not disassemble and repair by
non-repair technicians.
9. Care and Maintenance
The plug must be unplugged before maintenance. Do not remove
it with wet hands, otherwise it may cause electric shock and injury.
Maintenance of UV lamps:Take out the UV lamp every 6 months
and use a hair dryer to clean the dust accumulated on the surface or wipe
the lamp tube with 75% alcohol gauze to remove dust and oil stains.Do a
good job of cleaning the lamp tube to avoid affecting the purple
transmittance and radiation intensity;It is recommended to replace it
every 9000 hours of use.
Maintenance of TIO2 photocatalytic network:Take out the TIO2
photocatalytic network every 6 months and use a hair dryer to clean the
dust accumulated on the surface;It is recommended to replace it every
year.