Notes on the above listed sig nals

- The voltage pre sent on pins 1-2 is also used on the
MS2 con nec tor for re char ging the bac kup bat te ry.
- The si gnal on pin 3 must be mo nitored in tho se parti-
cu lar cri ti cal in stal la tions whe re it can hap pen to have
a strong si gnal re flec tion. In nor mal in stal la tion con di -
tions, it is suf ficient to align the units using a digital
voltmeter con nected to pin 8 (AGC) and pin 2 (GND).
- It is pos sible to con nect a LED with low current con -
sumption (2 mA) di rectly to pin 6 in or der to mo nitor
the alarm out put. Con nect to this pin loads lower than
5mA.
- The AGC si gnal on pin 8 must be mea sured with a di-
gital voltmeter. Wait at least for 10 se conds betwe en
each alignment test in or der to consider valid the mea -
su re.

PT4

: Trimmer for adjusting the RX speed de tection:

turn clockwi se to lower this pa rameter and on the op -
posite for in creasing it (see on the printed circuit for re -
fe ren ce si gnals).

PT5

: Trimmer for adjusting the RX sensitivity: turn

clockwise to lower this parameter and on the op posite
for in creasing it (see on the printed circuit for re feren-
ce si gnals).

MS2

: con nector for the bac kup bat tery; con nect the

12V 2.1A re char geab le bat te ry fol lowing the po la rity
indications marked on the printed circuit; the F1 fuse
(1A) is in se ries with the po sitive of the battery.
The bat te ry is au to ma ti cal ly char ged by the sup plier
inside each head. This battery gi ves the RX an auto-
nomy of over 36 hours in case of mains fai lure.

F1

: Battery protection fuse. See MS2 de scription.

U2

: TO- 220 vol ta ge re gu la tor, pro vi des vol ta ge re fe -

rence (13,8 VDC). TO- 220 me tal case is in sulated
from the me tal case.

Model HE400 mi cro wa ve barrier

DT01142 - Page 7

DOCU MEN TAZI ONE TEC NICA

TECH NI CAL DOCU MEN TA TION

Fig. 10: Re ceiver unit cir cuit board

Содержание HE400

Страница 1: ...ssed so that it causes an alarm re lay to be energized When an intruder approaches the beam the energy detected by the receiver causes if the predetermined level is reached the relay to be de energize...

Страница 2: ...overlapping of two barriers that are crossing or that are installed in parallel Plea se note that the uncovered area increases by decrea sing the sensitivity see Figure 4 Typically the height should b...

Страница 3: ...Model HE400 microwave barrier DT01142 Page 3 DOCUMENTAZIONE TECNICA TECHNICAL DOCUMENTATION Fig 4 Installation height of devices Fig 3 Attention to dead zones...

Страница 4: ...r parking guards may be used to protect equipment from damage from vehicles see Figure 7 Best security Choose the location that will provide best security yet be free from nuisance alarms Al ways loca...

Страница 5: ...tput N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of the contact is determined by a movement of th...

Страница 6: ...t of the trasformer PT0 PT1 tamper circuit output N C for protection against unauthorized openings movements or tampe ring In normal conditions there is a NC circuit 0 ohm voltage free The opening of...

Страница 7: ...X speed detection turn clockwise to lower this parameter and on the op posite for increasing it see on the printed circuit for re ference signals PT5 Trimmer for adjusting the RX sensitivity turn cloc...

Страница 8: ...lowing statement will be provided with the equipent as required by Article 6 3 of the R TTE Directive 199 05 EC HE400T is in conformity with all essential requirements of the R TTE Directive 1999 05 E...

Отзывы: