Frame Preparation*

Inches [mm]

© 

2011 HES, Inc.

3070006.001 rev B

1-1/4” [32]

1/8” [3]

4-7/8” [124]

4-1/8” [105]

3-3/8” [86]

*Note:  The 8500 electric strike will require removal of dust boxes of less than 1-3/8” in depth.
              Remove additional material as needed to provide clearance for electric strike and wires.

DIAGRAM 6: Horizontal Lockdown Shim Installation 

Remove Dust Box

1 Shim   =  1/16” [1.6]
2 Shims  

=  1/8” [3.2]

Содержание 8500 series

Страница 1: ...SOLENOID VOLTAGE 12VDC 24VDC 200 feet or less 200 300 feet 300 400 feet 18 gauge 16 gauge 14 gauge 20 gauge 18 gauge 16 gauge ELECTRICAL RATINGS FOR SOLENOID CONTINUOUS DUTY 12VDC 50 24 24VDC 200 50 200 12 12 12 16VAC 24VAC INTERMITTENT DUTY Resistance in Ohms Amps Solenoids are rated at 10 indicated value 10 max duty cycle 2 min max on time 24 32 2 3 4 8500 Electric Strike Body Horizontal Lockdow...

Страница 2: ...ng are aligned It may be necessary to slightly retract the keeper in order to properly seat the deadlatch platform fastening foot 6 Fasten the deadlatch platform to the electric strike using the 4 40 screw provided Install Strike in Frame 7 Select and electrically connect the appropriate 12 or 24 Volt pigtail to match system power as illustrated in Diagram 1 below For 12V AC DC or 16V AC the pigta...

Страница 3: ...d apply a lubricant to the inside of the latchbolt opening with the latchbolt depressed See Figure 2 Check manufacturer for proper maintenance and approved lubricants If this does not correct the friction additional maintenance on the latchbolt may be required Most doors experience some sagging over time To check for door sag look at the location of the lock s deadlatch in relation to the 8500 s d...

Страница 4: ... lockset Schlage 852M Compatible with mortise locksets Yale 8700 8800 Accurate Falcon Kaba Ilco Unican 4 centerline of faceplate 2nd line centerline of faceplate opening 23 32 18 2 C L 25 32 19 8 C L 25 32 19 8 C L 23 32 18 2 C L 25 32 19 8 C L 23 32 18 2 C L 25 32 19 8 C L 23 32 18 2 C L Manufactured after 2005 Contact HES Customer Support for more information ...

Страница 5: ...ail Safe DIAGRAM 3 LBM LBSM DIAGRAM 2 Fail Safe Conversion DIAGRAM 4 Deadlatch Platform Position Position 2 Strike shown in LH RHR position DIAGRAM 5 Deadlatch Platform Installation Position 1 RH LHR Position 1 LH RHR Brown Blue Yellow Platform Position 1 Platform Style Lockset Sargent 8100 8200 9200 Yale 8800 Accurate Falcon Kaba Ilco Unican M Yale 8700 Schlage L9000 M L Platform Position 2 Platf...

Страница 6: ...8 105 3 3 8 86 Note The 8500 electric strike will require removal of dust boxes of less than 1 3 8 in depth Remove additional material as needed to provide clearance for electric strike and wires DIAGRAM 6 Horizontal Lockdown Shim Installation Remove Dust Box 1 Shim 1 16 1 6 2 Shims 1 8 3 2 ...

Отзывы: