1. Prepare door jamb per appropriate
template detail. (See Figures 1-5). (See
NOTE 1.)
2. Install mounting tabs, when applicable.
(P/N 152: universal mounting tabs) using
four 10-32 UNF screws (see Figure 5). Do
not tighten.
3. Unplug wire pigtail from electric strike.
4. Connect wires coming from the low
voltage power source (see wiring
diagrams and electrical specifications on
page 6) to the electric strike pigtail.
5. Re-connect the pigtail to the electric
strike.
6. Install electric strike and option faceplate
to jamb, using two 12–24 UNC machine
screws or wood screws provided in the
option package.
7. Tighten the four10-32 UNF screws
holding mounting tabs (when applicable).
NOTE 1: It is important to allow enough
space behind the electric strike in the
jamb cut-out for the wires. Bunching
the wires inside the electric strike body
may cause the unit to not operate
properly.
NOTE 2: Use only the mounting screws
and hardware supplied with the product
for installation. Do not substitute
installation fasteners or hardware.
NOTE 3: HES offers a universal mounting
tabs & universal Metal Template Kit (P/N
154:MTK), sold separately, to simplify
the installation procedure.
©HES 2005
2
8
[203.2]
4
[101.6]
3/8
[9.53]
1-1/4
[31.8]
1-3/4
[44.45]
3/4
[19.05]
3-3/8
[85.73]
4-7/8
[123.83]
3-1/2
[88.9]
3/8
[9.53]
3/8
[9.53]
4-1/8
[104.77]
12-24 UNC
THREADS
STRIKE
LOCK
VERTICAL
CENTERLINE
5/8
[15.88]
1-1/4
[31.8]
MORTISE
LOCKSET
STRIKE
PLATE
MORTISE LOCKSET DOOR &
STRIKE JAMB DESCRIPTION
METAL JAMB INSTALLATION
FOR 1006 SERIES FACEPLATES
METAL JAMB INSTALLATION
FOR 1006 D SERIES FACEPLATES
4-
1
/
8
[
10
4.
77
]
3
-
3
/
8
[
85
.
72
]
4-
7
/
8
[
123
.
82
]
1
-
1
/4
[
31
.
75
]
1
-
11
/
16
[4
2
.
86
]
12
-
2
4
UNC THREADS
Cutout dimensions for option faceplates: J,
K, KM, N, NM, A, AM, H, HM, HT, T, Z, R
and E.
Cutout dimensions for option faceplates: KD,
ND, AD, HD AND TD.
4-
1
/
8
[
10
4.
77
]
3
-
3
/
8
[
85
.
72
]
4-
7
/
8
[
123
.
82
]
1
-
1
/4
[
31
.
75
]
1
-
11
/
16
[4
2
.
86
]
12
-
2
4
UNC THREADS
29
/
32
[
23
.
01
]
5
/
32
19
/
32
[
15
.
08
]
3
-
3
/
8
[
123
.
82
]
9
[
228
.
6
]
1
-
11
/
16
[4
2
.
86
]
1
-
3
/
8
[
3
4.
92
]
WOOD JAMB INSTALLATION
FOR 1006-2 SERIES FACEPLATES
FIG. 5
Cutout dimensions for option faceplates: J2,
K2, KM2, N2, T2, H2, A2
2
-
1
/4
[
57
.
15
]
1
-
1
/
8
[
28
.
57
]
1
-
1
/4
[
31
.
8
]
1
-
3
/4
[44.4
5
]
CYLINDRICAL
LOCKSET
VERTICAL
CENTERLINE
STRIKE
PLATE
3
/4
[
19
.
05
]
3
-
3
/
8
[
85
.
73
]
4-
7
/
8
[
123
.
83
]
3
-
1
/
2
[
88
.
9
]
3
/
8
[
9
.
53
]
3
/
8
[
9
.
53
]
4-
1
/
8
[
10
4.
77
]
12
-
2
4 UNC
THREADS
STRIKE
LOCK
5
/
8
[
15
.
88
]
1
-
1
/4
[
31
.
8
]
CYLINDRICAL LOCKSET DOOR &
STRIKE JAMB DESCRIPTION
Please note the horizontal centerline of
electric strike in reference to the horizon-
tal centerline of the mortise lockset.
Please note the horizontal centerline of
electric strike in reference to the horizontal
centerline of the cylindrical lockset.
FIG. 4
FIG. 3
FIG. 1
FIG. 2
INCH [MM]
4036006.001 rev B
1006 Series Installation Instructions