How it Works:
Under the condition that the power supply is connected, and the fan heater works normally, the heat dissipating equipment will work and
generate heat and the temperature controller is connected to the per fusion fan and starts working. The impeller of the fan rotates at a high speed
and extracts the surrounding air to enter the body of the fan heater through filter screen. The flowing air crosses a specially designed air duct and
the heating heat dissipating equipment to make the heat in the body efficiently transmitted out from the air distributor of the front plate. The
warm current transmitted out will increase the indoor air temperature to reach the heating effect.
The ideal heating area of the fan heater is from 20m
2
to 30m
2
.
The maximum heating area is 40m
2
only for a single room. The temperature rise
effect is mainly dependent on the ambient temperature around the fan heater.
Functions and Composition:
A.
This heater is composed of some quartz heating tube and resistance wire heating elements. The total power is 1,500W. These heating
components generate infrared rays with the function of physical therapy which pass through the box and heat the air.
B.
AC per-fusion heater imports the air flow to the movement installed with quartz heating tube. The per-fusion heater utilizes impeller to generate
extensive air flow. The air flow is then absorbed inside the heater and circulates around the quartz heating tube with the temperature inside
the box. Later, it will be spread out as a unique warm air flow.
C.
The operating system of this fan heater controls the simultaneous operation of AC per-fusion fan and heating coil. When the working
temperature is too high, the temperature controller will stop working automatically to protect the product. When the temperature of the
temperature controller drops to a certain degree, the temperature controller will be actuated, and the product resumes the normal working
status.
D.
This heater has a delayed heat dissipation function to control AC per-fusion fan. AC per-fusion fan will work continually after the power supply
on the control panel is cut off and circulate the air and cool the heater.
E.
The control of the running program of fan heater is of logicality. It can be implemented through control panel and remote. See the operation
guide for details.
Unpacking of Heater:
1.
Check the carton first to make sure it is free from obvious damage during transport.
2.
Open the packing of heater and slowly slide it out. It is available to gently and carefully turn the whole box over to make the heater slide out
slowly.
3.
Remove all protective materials and properly collect the protective materials which may be used to wrap the heater again in seasons when the
cabinet is not needed.
Operation Guide:
Check if the heater is damaged first before operation. If any damage is found, please do not use it and contact with the supplier immediately.
ATTENTION:
The operation functions of the remote control are same as those of the front control panel. You can operate the
heater either use remote control or the front control panel. The meaning of symbols and words as bellowed:
(ON/OFF) Power Switch
Turn on or turn off the heater.
(TEMP
↑
) UP arrow
Increase the setting temperature you want (
℃
)
(TEMP
↓
) DOWN arrow
Decrease the setting temperature you want (
℃
)
(MODE) 2 Modes
“
MAX
”
mode and
“
AUTO & Energy-saving
”
mode.