Configuration menu
10.5 S
etting
routine
deScaling
(
d
ec)
The ETKF+ Radiator Thermostat can protect against valve
calcification automatically. Therefore, an automatic routine
descaling is performed once a week. During this brief period,
when the valve opens and closes once, operation is not pos-
sible. The time for performing this function can individually
be configured (it is factory set to run at 12:00 on Saturdays).
In the HERZ Room solution you can configure the set-
tings for the ETKF+ Radiator Thermostat via the Wall
The.
If you use the ETKF+ Radiator Thermostat in the HERZ
Radiator solution, proceed as follows:
• Press the Auto/Manu button longer than 3 seconds.
• Select the menu item "dEC" with the handwheel.
• Confirm your setting using the Boost button.
• Use the handwheel to select the weekday and confirm this
with the Boost button.
• Use the handwheel to select the time and confirm this
with the Boost button.
“CAL” is displayed during descaling.
10.6 S
witching
time
/
date
diSplaY
(
t
-
d
)
The factory setting will show the time on the display. In the
menu the display can be switched to the date.