background image

Enter  menu Set2, by turning the knob select the combination of 
days which is required. Confirm by briefly pressing the knob. 

Programming always starts at 00 hours. By 
turning the knob clockwise, you can move 
through the time line. Press the knob at the 
point from which you want to start with heating 
to comfort temperature. By turning the knob 
now there will be points visible which represent 
the hours of heating to economy temperature. 
By turning the knob anti clockwise the points 
are erased. Pressing the knob switches 
between economy and comfort temperature. 
After programming of the whole day has been 
finished, the thermostat shows you OK. When 
the knob is pressed all settings are saved.

Set3 - Service menu

In this menu service parameters can be changed. Under common  
circumstances it is not necessary to change any of those 
parameters. 

Hysteresis is the accuracy to which the 
temperature is regulated. The setting is done 
via the HYst item in the adjustment menu. 
Turning the knob lets select you one of the 
following accuracy ranges: ±0.1°C to ±1°C 
(factory setting: ±0.2°C)
Example: If the accuracy is adjusted to 
±0.5°C and the temperature is set to 24°C, 
the thermostat switches the heating on 
when the temperature drops below 23.5°C 
and switches it off if the temperature goes 
above 24.5°C. In reality the temperature 
scatter can be slightly higher because of the 
temperature persistence of the room.
Warning: Too high accuracy can cause the 
heating to turn on and off to frequently.

The item Stby sets the temperature which 
will be kept in the case of switching off ther 
thermostat (item OFF). The Stby temperature 
is always at least 3°C higher than ALLo. The 
value of the  Stby temperature does not have 
to be set higher than the t Lo tmperature.

The t Lo item is the lower limit to which 
economical temperature can be set.

The t Hi item is the upper limit to which the 
comfort temperature can be set.

AL Lo is the lower critical temperature. When 
the temperature drops under the preset 
value, the thermostat sends an alarm report 
to the receiver and this state is indicated 
by a permanently lit (!) symbol. The ALLo 
- temperature is always at least 3°C lower 
than t Lo.

AL Hi is the upper critical temperature. When 
the temperature increases above the preset 
value, the thermostat sends an alarm report 
to the receiver and this state is indicated 
by a permanently lit (!) symbol. The ALHi 
temperature is always at least 3°C higher 
than tHi.

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

This item allows to turn the adaptive pre-
heating On or Off according to the heating 
system inertia. When auto modus is enabled, 
the thermostat starts measuring the time 
after which it has reached the requested 
comfort temperature and according to this 
time it starts the heating. 

The reset function allows you to reset the 
device to factory settings (listed in table). You 
can perform reset by selecting Res in the 
menu and pressing the knob and choosing 
the menu Res.

By pressing the OK item you are leaving 
the service menu and return to the basic 
thermostat menu
   

Settings 
item

Range 

Factory 

settings

Description

HYst

0.1°C to 1°C

0.2°C

Hysteresis

t Lo

+6°C to +40°C

6°C

lower limit of 

temperature

t Hi

+6°C to +40°C

40°C

upper limit of 

temperature

AL Lo

-9°C to +20°C

3°C

Panic Alarm

AL Hi

+30°C to +70°C

60°C

Fire alarm

+6°C to +40°C

18°C

Economical 

temperature

+6°C to +40°C

21°C

Comfort 

temperature

Party mode

In this mode it’s possible to raise or 
decrease the temperature for an defined 
amount of time. Party modus can only be 
entered from the weekly programm. When

the defined time expires the thermostat will start again the weekly 
schedule.
Party modus is entered when the display shows the (  )-symbol.
The first value is time (hours) after which the thermostat returns 
to the weekly program. After time settings temperature settings 
have to be done. The party mode is indicated by the (  )-symbol 
on the display. If you want to leave teh party mode earlier than the 
defined time, then the thermostat have to be set back to weekly 
schedule.

Holiday mode

The holiday mode is designed to save costs 
of the costumer. During vacation it is not 
necessary to keep the temperature of the

weekly schedule. Like party modus, holiday mode is only possible 
to enter from the weekly program.
If the holiday mode is entered the thermostat shows a flashing 
value of days for which the economical temperature has to 
be kept. The countdown starts from the moment of setting. 
Substraction is done every day at midnight. When holiday mode 
expires the thermostat returns to the weekly program.

Showing the pre-set temperature

The thermostat always shows the current room temperature in the 
normal mode. Pressing the knob will show the temperature which 
has been set for this time. 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

 TP-150 wireless indoor thermostat  

 

The TP-150 is a wireless indoor thermostat. It serves for the measuring and 

regulation  of  temperature. The temperature is set by the knob. The 

thermostat regulates a pre-set temperature 24hrs per day.  

The thermostat can be locked against unwanted manipulation. As well 

as the regulation of temperature it can also report reaching the high and 

low temperature limits. 

 

 

Figure1

: 1 - knob (encoder) combined with button 2 - tab 

  Thermostat installation 

The product can only  be  used  in  an  indoor environment.  Install the 

thermostat 1.5 m above the floor in a place where there is good natural air 

circulation.  Don´t install the thermostat where the measuring can be 

influenced by drafts, sunlight, heaters or any other effects.  Avoid mounting 

the thermostat on metal objects  or metal bases which block radio 

communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of 

the thermostat. 

2.  Install the rear part of the thermostat at the choose place (tab down). 
3.  Insert the batteries; the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it.  

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the 

receiver has been bought independently, you have to enroll the thermostat to 

it first. Open the enrollment mode on the receiver (see its manual) and insert 

the batteries into the thermostat or press and hold the knob for 5s. In both 

cases the thermostat will send an enrollment signal. The text 

LRn 

appears on 

the LCD display when the enrolling procedure (with AC-116 only) has been 

done successfully.  

 

Symbols on the LCD: 

 

Figure 2: 1 – Symbols of temperature and texts; 2 – Locking the thermostat; 

3 – Alarm temperature-limits / Loss of communication; 4 – Heating ON / OFF; 

5 – Low battery  

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 

sec enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows  changing  the option(s) or 

choosing a next item. 

2.  Perform choosing or changing  by turning the knob (turning the knob is 

possible from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 
4.  When the value of an item has been changed, then after this briefly press 

the knob and the changes are saved. Then the thermostat goes to the 

next item in the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, 

in the menu. By short pressing the system returns back to the previous 

menu (up to the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to 

the previous menu automatically. 

The basic menu has 4 groups of settings.  

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t3

 

Service menu 

OK

 

Saving the parameters and leaving the service menu 

 

1.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation 

you can lock the thermostat. Enter the menu and press 

the knob on item 

LOc

, the options 

ON/OFF 

appear. By 

turning the knob select the requested state and confirm 

by pressing. Choosing 

ON

  enables  the function 

Lock

, and blocks  thermostat 

control.  To unlock the thermostat choose the  option 

OFF. 

Locking the 

thermostat is indicated on the LCD by the 

 symbol. 

2.   OFF – Switching off the thermostat 

The thermostat can be switched off by the option 

OFF

Enter the menu and press the knob on the  item 

OFF,

 

the options 

ON/OFF

 appear. By turning the knob select 

the requested state and confirm by pressing. Choosing 

ON

  enables  the  function 

OFF

,  and  switches  off  the thermostat.  This is 

indicated on the LCD by the  text 

OFF

.  Although the thermostat has been 

switched off, it still measures and detects the antifreeze temperature (see SE 

t3, Stby).  To unlock the thermostat enter the  menu and choose the  option 

OFF

. When the knob is pressed the thermostat will be unlocked. 

 

3.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In a normal mode it is not 

necessary to change those parameters. The Service menu includes 8 items. Open 

by scrolling the knob to the requested item and by pressing the knob enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

 

 

HYst 

is an item, where you can program the range of 

the switching thresholds  around the requested 

temperature (hysteresis). The range can be set with a 

0.1°C step from 0.1°C to 1°C. (Default setting 

±

0.2°C) 

Example: 

With a set accuracy  of  ±0.

5˚C 

a  temperature  of 

24°C 

will be kept  this 

way, at 23.

5°C it starts heating and  at 24

.

5°C 

it 

stops heating.

 

In real conditions 

regulation could have 

a much bigger temperature scatter because of the thermal 

inertia in 

the 

heated 

premises.  

Warning: An over-narrow pre-programmed hysteresis range could perform 

on/off switching of the heating very often. 

 

 

The item 

Stby 

sets the temperature which will be kept 

in the case of switching off the thermostat (item 

OFF

). 

The 

Stby

  temperature  is always at least  3°C higher 

than 

ALLo.

  The value of  the 

Stby

  temperature  does 

not have to be set higher than the 

t Lo

 temperature. 

 

The 

t Lo

  item  is  the lower  limit to which economical 

temperate can be set. 

 

The 

t Hi 

item is the  upper  limit to which  the  comfort 

temperature can be set. 

 

AL Lo 

is  the  lower  critical temperature.  When  the 

temperature drops under the pre-set value, the 

thermostat sends an  alarm report  to the receiver  and 

this state is indicated by a  permanently  lit  (

!

) symbol. 

The 

ALLo

  temperature  is always  at least 3°C  lower 

than 

tLo

.

 

 

AL Hi 

is  the upper  critical temperature. When the 

temperature increases  above the pre-set value, the 

thermostat sends an  alarm report to the receiver and 

this state is indicated  by a permanently  lit  (

!

) symbol. 

The 

ALHi

  temperature is always at least  3°C  higher 

than 

tHi.

 

 

For a reset to factory default settings the 

RES

 item is 

used

.

 After you enter the menu and press the knob on 

the 

RES

 item 

ON/OFF

 appears. By scrolling the knob 

select 

ON,

 and press the knob. Then a RESET will be 

done.

 

When the reset is finished, a 20°C temperature 

is pre-set. 

 

By pressing the knob when the thermostat shows you 

OK 

you leave the service menu and return to the basic 

thermostat menu. 

 
 

TP-150 wireless indoor thermostat 

1 / 2 

MMC51601 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

TP-155 Wireless programmable indoor thermostat  

 

The TP-155 is a wireless programmable indoor thermostat with a weekly heating 

schedule.  It can regulate the 

economical  or comfort temperature 

inside residential buildings. It offers a 

few programmable modes. Every 

mode regulates pre-set temperatures 

(Comfort, Economy, Holiday,  and 

Party). The thermostat is able to 

measure the thermal inertia inside the 

premises and adjust the weekly 

schedule 

for the requested 

temperature to be reached at the pre-

set time.  

 

Figure 1

: 1- knob (encoder) combined with button; 2- tab 

  Thermostat installation 

The product can only be used in an indoor environment. Install the thermostat 1.5 

m above the floor in a place where there is good natural air circulation. Don´t install 

the thermostat where the measuring can be influenced by drafts, sunlight, heaters or 

any other effects. Avoid mounting the thermostat on metal objects or metal bases 

which block radio communication. 

1.  By pressing the tab (by screwdriver for instance) release the front part of the 

thermostat. 

2.  Install the rear part of the thermostat at the chosen place (tab down). 
3.  Insert the batteries, the polarity is marked on the plastic. 
4.  Put back the front thermostat part and close it. 

  Enrolling the thermostat 

Install and connect the receiving unit to the heating appliance. If the receiver has 

been bought independently, you have to enroll the thermostat to it first. Open the 

enrollment mode on the receiver (see its manual) and insert the batteries into the 

thermostat or press and hold the knob for 5s. In both cases the thermostat will send 

an enrollment signal. The text 

LRn 

appears on the LCD display when the enrolling 

procedure (with AC-116 only) has been done successfully.  

 

Symbols on the LCD:

 

Figure 2: 1 –  Symbols  for 

comfort    and  economical   

temperatures; 2 – The days of 

the  week; 3 – Locking the 

thermostat;  4 – Alarm  tempe-

rature 

– 

limits / loss of 

communication; 5 – Heating 

ON / OFF; 6 – Holiday; 7 – Party; 

8 – Heating times;  9 – Symbols 

for showing temperature time 

and texts; 10 – Low battery 

  Settings and programming 

Do the complete settings using the knob – encoder. By pressing the knob 2 sec 

enter the programming mode. 

General rules for programming: 

1.  Flashing of any icon on the LCD allows changing the option(s) or choosing a 

next item. 

2.  Perform choosing or changing by turning the knob (turning the knob is possible 

from left to right and vice versa). 

3.  Confirm the selection or change by briefly pressing the knob. 

4.  When the value of an item has been changed, then after this briefly press the 

knob and the changes are saved. Then the thermostat goes to the next item in 

the programming menu. 

5.  After the setting / change of the chosen items, select the parameter „OK“, in the 

menu. By short pressing the system returns back to the previous menu (up to 

the main menu).  

6.  If there is no manipulation of the knob for 30 sec, it returns you back to the 

previous menu automatically. 

The basic menu has 7 groups of settings.  

 

MA

 

n

 

Manual mode 

LO

 

c

 

Locking the thermostat 

OF

 

F

 

Switching off the thermostat 

SE

 

t1

 

Temperature, date and time settings  

SE

 

t2

 

Weekly schedule setting 

SE

 

t3

 

Service menu 

OK 

Saving the parameters and leaving the service menu 

1.  MAn – manual mode 

The temperature is set manually regardless of  the weekly 

schedule and is kept. Enter the menu and press the knob on 

the  item 

Man,

  the option ON (switched on) appears. By 

turning the knob select the requested state and confirm by 

pressing.  The temperatures 

tLo

  and 

tHi

  determine the regulation range  pre-

programmed in the service menu SE t3, in which you can select the temperature by 

turning the knob. Choose the requested temperature. If the chosen temperature is 

lower than the required temperature, the thermostat shows the symbol 

(▲)

  on its 

LCD display.  By entering the menu 

Man

  and confirming the option 

OFF

, manual 

mode is terminated. 

2.  LOc – Locking the thermostat 

To protect the thermostat against unwanted manipulation you 

can lock the thermostat. Enter the menu and press the knob 

on the item 

LOc,

 the options 

ON/OFF

 appear. By turning the 

knob select the requested state and confirm by pressing. 

Choosing 

ON

 enables the function 

Lock

, and blocks thermostat control. To unlock 

the thermostat choose the option 

OFF.

 Locking the thermostat is indicated on the 

LCD by the 

 symbol. 

3.  OFF – Switching off the thermostat 

The thermostat  can be switched off by the option 

OFF

Enter the menu and press the knob on the item 

OFF,

 the 

options 

ON/OFF

  appear.  By turning the knob select the 

requested state and confirm by pressing. Choosing 

ON

 

enables the function 

OFF

, and switches off the thermostat. This is indicated on the 

LCD by the text 

OFF

.  Although  the thermostat has been switched off, it still 

measures and detects the antifreeze temperature (see SE t3, Stby). To unlock the 

thermostat enter the menu and choose the option 

OFF.

 When the knob is pressed 

the thermostat will be unlocked. 

4.  Set1 - Temperature, date and time settings 

In the Set1 menu the comfort temperature ( ), the economy 

temperature ( ), the temperature for Holiday mode ( ), and 

the data and time can be preset. Enter the menu 

Set1

, and 

on the LCD the symbol of the economy temperature starts 

flashing. By turning the knob select the requested item ( ,  or  ), by pressing the 

knob the symbols for temperature start flashing and again by turning the knob set the 

required temperature and by repeatedly pressing the knob confirm this setting. The 

last item serves for setting the current time. It indicates using flashing symbols of the 

days of the week. By pressing you enter the current time setting. It starts with the 

year. Pressing gets  it flashing, and by turning the knob set the year, by pressing 

again it saves the setting and then you continue the same way in setting the current 

month, day, hour and minute. Then by pressing the knob after the minute setting the 

values are saved and the thermostat is back in the menu 

Set1

. Select the item 

OK

 to 

leave this menu. 

 

5.  SEt2 – Weekly schedule setting 

The heating program for switching the comfort and the economy temperatures can 

be set for every single day independently  (Mo -  Monday, Tu -  Tuesday,  We - 

Wednesday, Th - Thursday, Fr - Friday, Sa - Saturday, Su - Sunday) or it can be 

split into working days and the weekend. There is one more option - the same 

settings for all days with no difference. 

 

Enter the menu 

Set2

, and by turning the knob select the combination of days which 

is required. Confirm by briefly pressing the knob. It enters the programming of heating 

time periods  when the thermostat switches between the day temperature and the 

night temperature.  

 

Programming always starts at 00 hrs. By turning the knob 

clockwise, you can move through the time line. Press the 

knob  at  the point from which you want to start with the 

heating to the comfort temperature. The   symbol changes 

to  the  .  Now by turning the knob clockwise  the points 

appear  which represent  the hours  for which heating is 

performed  to the economy temperature.  By turning the 

knob  anti-clockwise  the points are erased.  Pressing the 

knob  more  switches the economy temperature to the 

comfort temperature.  By repeating this procedure the 

comfort and economy temperatures can be set for  a 

selected day (or for a  group of a  few  days). After the 

programming of the  whole day has been finished, the 

thermostat shows you 

OK

. When the knob is pressed, all 

settings are saved.  

 

 

 

 

 

6.  SEt3 – Service menu 

The service parameters can be pre-programmed here. In normal mode it is not 

necessary to change those parameters. The Service menu includes 9 items. Open 

by scrolling the knob to the requested item and by pressing the knob to enter the 

programming mode. Select the value again by scrolling the knob. Confirm it by 

pressing the knob and it returns you back to the service menu. 

TP-155 Wireless programmable indoor thermostat 

1 / 2 

MMC51701 

Отзывы: