118
EN
vals by the operator themselves and that may only
be performed by an authorised service centre for the
HERON® brand.
To exercise a claim to warranty repairs, it is neces-
sary to present/provide documentation of proof
of purchase and performed servicing inspections
- tasks. These records are entered into the second
part of the user's manual designated as "Warranty
and service". Not presenting/providing servicing
records will be deemed to constitute neglected
maintenance, which will result in loss of guarantee
according to the warranty conditions.
In the event of a malfunction on the generator and the
submission of a claim to free warranty repairs, the failure
to adhere to these service tasks represents grounds for
rejection of the warranty on the basis of neglect of mainte
-
nance and non-adherence to the user's manual.
To extend the lifetime of the generator, we recom
-
mend that a complete inspection is performed after
1200 hours of operation, including repairs, covering
the following tasks:
y
the same tasks according to the maintenance plan after
every 200 hours and the following tasks that may only
be performed by an authorised service centre for the
Heron® brand:
y
inspection of the crankshaft, piston rod and piston
y
inspection of collector rings, carbon brushes of the alter
-
nator or shaft bearings
MAINTENANCE PLAN
•
ATTENTION
y
Not adhering to the servicing tasks in the main-
tenance intervals provided in table 4 may lead to
a malfunction or damage of the generator, which is
not covered by the free warranty repair.
Always perform in the here
specified operating hour intervals
Before
every use
After first
5 hours of
operation
Every
50 oper.
hours
Every
100 oper.
hours
Every
300 oper.
hours
Maintenance task
Motor oil
Check oil level
X
Replacement
X
(1)
X
Air filter
Check condition
X
(2)
Cleaning
X
(2)
Spark plug
Inspection,
adjustment
X
Replacement
X
Valve movement
Inspection-
adjustment
X
(3)
Fuel line
Visual inspection
of tightness
X
(5)
Inspection
and replacement
if necessary
Every 2 calendar years (replacement as necessary) X
(3)
Fuel tank
strainer
Cleaning
After every 500 operating hours X
Fuel tank
Cleaning
After every 500 operating hours X
(3)
Fuel filter
(fig. 14, position 1)
Replacement
X
Oil filter
(fig. 14, position 5)
Replacement
X
(3)
Combustion cham-
ber
Cleaning
After every 500 operating hours X
(3)
Fuel valve
Purging
X
Electrical part
Inspection/mainte-
nance
Every 12 months from purchase X
(4)
Table 5
Содержание 8896430
Страница 127: ......