#HeroCamper™ –
Lammefjordsvej 5
–
6715 Esbjerg N
–
Denmark
Phone +45 7022 5840
–
www.herocamper.com
VAT No DK -40193189
Page
15
of
92
•
Match the corresponding active (brown),
neutral (blue) and ground wire (yellow-
green) and tighten up screws to make
sure power is properly connected.
•
Insert plenum mounting bracket through
the ceiling to base. Pay attention as the
“C” h
ook must match the corresponding
“C” area on the base. Finally fasten.
•
Insert 4xM8 bolts, washers, spring
washer and metal plate via mounting
frame to the base.
•
Tie the room temperature sensor onto
the rib of mounting bracket.
•
Plug the connectors on the plenum to
the base. Push plenum into outlet duct and
fasten 4xM4 screw on the bottom. Finally
add the filters to the sides of the plenum.
Important: ensure the tightening
torque from 12 to 14 N.m