HERO PW3540-AC Скачать руководство пользователя страница 5

H.E.R.O. Industries                  PW-3540-AC        Pressure Washer Owners Manual 

Page 5 

START-UP AND OPERATION INTRODUCTION 

SHUTTING DOWN THE MACHINE AFTER USE 

7.   Select the desired tip for the job. Insert tip into wand ( quick-connect fittings ). See page 6. 
      RED-0º, 

Narrow Fan,  Direct or Concentrated Cleaning

      YELLOW - 15º, 

Medium Fan

General Use.

 

      WHITE - 40º, 

Wide Fan, Soft Pattern, For Rinsing.

 

      BLACK - 65º, 

Chemical Injector Tip

Must be used when operating chemical injector

 

 
8.  If you are not going to be using injector system, remove the injector components 
      from the out put side of the unloader. All components feature quick release  
      fittings. Store for future use. 
 
9.  Turn on the water supply and trigger the spray gun to purge all air from the sys-
tem, 

PRIOR 

to     starting engine. 

 
10.     Start the engine by following this procedure: 
           - Turn the ON/OFF switch to ON. 
           - Turn the GAS to ON. 
           - Turn the CHOKE to FULL. 
           - Push the THROTTLE lever to the ON position. 
           - Pull the STARTING cord. 
           - Once the engine has started, reduce the CHOKE until it is OFF, and open the THROTTLE to  
           full ON. 

Use these instructions in conjunction with instructions provided in the Honda manual.

 

 
11.     At this point, the gun is triggered to evacuate any remaining air in the system. Then trigger the  
           gun and  begin turning the BLACK unloader knob in a clockwise direction as far as it will turn.  
           You should now have full pressure. 
 
12.     To introduce chemicals/detergent to the spray,   
           - Turn unit off, and trigger gun to relieve all internal fluid pressure. 
           - Re-connect the chemical injector components as removed in step 8.  
           - Connect the detergent/chemical suction line to the fitting marked “Injector” and place the filter 
           end into the chemical/detergent jug. 
           - Install “Black” injector tip into gun. VERY IMPORTANT. 
           - Re-start pump and set pressure to low. 
           

Injector siphoning is best at very low pressure. Once the injector material stream has been  

           established, the pump operating pressure can be increased.

 

 
 

Содержание PW3540-AC

Страница 1: ...anual Page 1 H E R O Industries a division of Middlefield Bancorp Limited 2719 Lake City Way Burnaby B C Canada Phone 604 420 6543 Fax 604 420 8725 Toll Free 1 800 494 4376 E mail sales hero ca Websit...

Страница 2: ...riod of two years from the date of purchase when operated and maintained in accordance with the Maintenance and Operation Instructions supplied with the unit The warranty does not cover misuse or negl...

Страница 3: ...e doing Keep operating area clear of all persons Follow the maintenance instructions specified in the manual Do not operate the machine when fatigued or under the influence of alcohol or drugs Do not...

Страница 4: ...ded Before each use check engine oil level by unscrewing the oil dipstick Add motor oil consult Honda manual for correct grade as required to bring to proper level approximately mid way on dipstick 3...

Страница 5: ...HOKE to FULL Push the THROTTLE lever to the ON position Pull the STARTING cord Once the engine has started reduce the CHOKE until it is OFF and open the THROTTLE to full ON Use these instructions in c...

Страница 6: ...r machine is equipped with a 0 15 40 and a chemical nozzle If you require a different cleaning action we suggest selecting the correct tip for the job 1 RED 0 Angle High impact solid stream 2 YELLOW 1...

Страница 7: ...water supply source Pressure drops after period of normal use Nozzle worn Valves worn dirty or stuck Unloader valve packing worn Worn piston packing Check and replace Check clean or replace Check clea...

Страница 8: ...H E R O Industries PW 3540 AC Pressure Washer Owners Manual Page 8 PW3540 AC WW965 Pump Assembly...

Страница 9: ...0 PW 98 2226 00 Cap Kit 124 6 11 PW 36 7115 01 Valve Unit Kit 123 6 12 PW 99 1807 00 Screw 4 13 PW 50 1500 74 Side Cover 1 14 PW 44 2118 01 Indicator Spacer 1 15 PW 90 4097 00 O Ring 1 16 PW 91 8328 0...

Страница 10: ...53 156 3 52 PW 1075 Valve Thermal Protection 1 2 1 53 PW 1405 Tubing P R V 1 75 PW 90 0635 00 Circlip 1 76 PW 44 0221 65 Crankshaft WW965 1 77 PW 91 8568 00 Bushing 1 78 PW 90 4097 00 O Ring 1 79 PW 9...

Страница 11: ...H E R O Industries PW 3540 AC Pressure Washer Owners Manual Page 11 UNLOADER PW 1195 667 10...

Страница 12: ...PW 10 4021 00 Backup Ring 2 11 PW 10 3175 08 O Ring 2 12 PW 60 0061 23 S S Piston 2 13 PW 10 3170 08 O Ring 1 14 PW 10 4020 00 Backup Ring 1 15 PW 60 0064 31 Piston Housing 1 16 PW 15 1021 00 Locking...

Страница 13: ...Connector 3 8 male x 3 8 male 1 2 PW 1165 Fitting 3 8 hose x 3 8 NPT 1 3 PW 1250 Elbow 4 PW 1052 Body Quick Disconnect Female x 3 8 Male threads 1 5 PW 1255 Chemical Injector only 1 6 PW 1175 Garden H...

Страница 14: ...ug Quick Disconnect 3 8 Steel Male 1 PW 1470 Assembly Pressure Washer Hose 50 complete with fittings PW 1057 Male plug PW 1050 female Q D PW 1235 hose Assy PW 1100 0004 Spray Nozzle 0 Degree RED 1 PW...

Страница 15: ...t valve assembly ref 4 A D 9 2 Examine o rings and replace if there is any evidence of cuts abrasions or distortion 3 Remove valve assembly ref A D from valve cavity 4 Remove o ring ref 4 from valve c...

Страница 16: ...urface Brush Telescopic Wand PW 9065 Window Brush Telescopic Wand PW 9070 Adapter PW 1065 Gauge 0 3000 psi PW 1070 Gauge 0 4000 psi PW 1110 Nozzle rotating 3000 psi less q c fitting HPWD 2500 3000 onl...

Страница 17: ...7 MODEL ___________________________________________________________ SERIAL ___________________________________________________________ PURCHASED ON ____________________________________________________...

Отзывы: