7
Technical data
fo
r the technician
BOILER SCHEMATIC
SUPERMASTER E
SUPERMASTER E
SUPERMASTER E
SUPERMASTER E
SUPERMASTER E
SUPERMASTER SE
SUPERMASTER SE
SUPERMASTER SE
SUPERMASTER SE
SUPERMASTER SE
1
DHW circuit safety valve (8 bar)
2
Manual DHW mixing valve (Knob
)
3
DHW expansion vessel
4
Tank drain tap
5
Tank Temperature sensor
6
Tank
7
Heating circuit filling tap
8
Heating circuit safety valve (3 bar)
9
Circulator
10 Motorized 3 way valve
11 Water pressure switch
12 Air outlet valve
13 Heating circuit expansion vessel
14 Heating temperature sensor
15 Safety thermostat
16 Flue thermostat
(“E” models)
Flue pressure switch
(“SE” models)
17 Fan
(“SE” models)
18 Chimney
(“E” models)
Flue Conveyor
(“SE” models)
19 Primary exchanger
20 Burner
21 Gas valve
22 Therm Heating circuit Gauge
23 Heating circuit drain tap
24 System By-pass
25 Filter
26 Litercounter
DOMESTIC
WATER
GAS
INLET
HEATING
FLOW
OUTLET
RETURN
DOMESTIC
WATER
GAS
INLET
HEATING
FLOW
OUTLET
RETURN
WARNING: This scheme is made for in-
formation only. To make boiler hydrau-
lic connection either use fixing jig or the
drawing inserted in the section “Instal-
lation” or the “Dimensions” drawing.