6
Flue Installation
The Flue type required: 152mm ( 6”) active flue and a solid 8” heat shield within the room, and air
cooled Double casing insulation (triple skin) from above the ceiling, as per AS2918:2018 default flue
kit. See diagrams below for flue requirements. The Active 152mm flue must be a tight fit into the
heater collar.
The heater must have its own dedicated flue. The active flue must be 6” for the entire length of
the flue, and always less than 45 degrees from the vertical.
Replacement room air from outside equivalent in open area to 91cm2 must be supplied into the
room.
Flue Outlet Positions
Minimum Flue Height as per AS/NZS 2918:2018
NOTE: Flue exit MUST also be as high as any nearby structure within a 6m Radius. ( AS
2918:2018 )