Paused Batch Run 

1.  To pause a batch in mid run, press the 

 

key until “PAUSE” is displayed. Press SELECT key to pause the 

batch run. 

2.  When paused, the indicator will d

isplay “PAUSE” and the remaining batch amount on the screen.  

3.  To restart the batch, press the 

 

key until “run” is displayed then press the SELECT key. The batch will then 

continue until completed. 

Fill Event During Batch Run 

1.  If a FILL event occurs just prior to a batch being enabled, the unit will switch to FILL batching mode until FILL 

event has completed. The unit will remain in FILL batching mode for 20 minutes after the FILL event is 
complete to calibrate the additional weight.  

2.  If this occurs during the time when a scheduled batch run is set to go, the scheduled batch run will be skipped. 

A manual batch run can be done at this time. 

3.  If a FILL event occurs while a batch is running and the weight increases by 50 lbs. or more in the bin, the 

BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed.  

4.  The unit will remain in FILL batching mode for 20 minutes after the FILL event is complete to calibrate the 

additional weight and then resume batching the remaining amount. 

 

Display Fill Events  

This procedure allows you to view the last four recorded fill events. 
 

5.  Press the  

 

key until “

Fill

” is displayed. 

6.  Press SELECT to view the last recorded fill event.   

7.  Press  

  key to view other prior recorded fill events. 

8.  Press SELECT to return to Weight Display mode or unit will return to Weight Display mode after 20 seconds of 

no activity (no key strokes). 

 

Display 24 Hour Usage  

This procedure allows you to view the last four 24 hour usage amounts. 
 

1.  Press the 

 

key twice until “

usage

” is displayed. 

2.  Press SELECT to view the last recorded 24 hour usage amount.   

3.  Press 

  key to view other prior recorded usage amounts.  

4.  Press SELECT to return to Weight Display mode or unit will return to Weight Display mode after 20 seconds of 

no activity (no key strokes). 

Содержание Bintrac

Страница 1: ...Operation Manual 12 1 2012 Breeder Control Operation Manual Patented U S Patent No 7 980 129 and Patents Pending...

Страница 2: ...n Option in Setup mode 5 Options in Setup Mode 6 Setup Version 1 0 and higher 6 Serial Data Command Set 6 Batch 7 Rated 7 Capacity 7 Increment Value 8 Full Value 8 Zero Value 8 Year 9 Month 9 Date 9 H...

Страница 3: ...es the signals from all brackets to minimize errors that could result from voids holes in the material Smart Summing Box A single Smart Summing Box per bin communicates the current reading on the leg...

Страница 4: ...key for approximately 8 10 seconds The bin level gauge will go blank and all of the bin selector indicators will illuminate showing their current status 1 Press the SELECT key to select the desired bi...

Страница 5: ...ce is powered up it will automatically enter SETUP mode and display the Ver 2 This method requires you to hold the SELECT button down for approximately 10 seconds at which time SETUP mode will be disp...

Страница 6: ...roadcast ASCII weight data will be serially broadcast approximately once ever second RUN Enable communications to peripheral devices Must be enabled when BinTrac Monitor is connected to BinTrac Remote...

Страница 7: ...ad cells DO NOT CHANGE unless necessary Every standard load cell has a rated output specified in mV V If using load cells other than the Herdstar load cells adjust this value appropriately 1 Press the...

Страница 8: ...units Segmented display Figure 2 Full Value Sets the maximum weight of a full bin either in pounds or kilograms It is how much material the bin can hold This is for calibration of the LED bar graph le...

Страница 9: ...the current Minute Segmented display Station ID Value Sets the Station ID of the device For devices interfacing with a Site Console the Station ID must be set within 100 131 When interfacing the devic...

Страница 10: ...CT key to see the software version number Segmented display Smart Summing Box Software Version Version 3 0 and higher Displays each of the connected Smart Summing Boxes programmed software version num...

Страница 11: ...h run control status run or Stop 6 Use the or keys to enable or disable batch run control 7 Press SELECT to start Batching if run was selected The batch run will begin immediately Scheduled Batch Run...

Страница 12: ...while a batch is running and the weight increases by 50 lbs or more in the bin the BinTrac WBBS will pause the batch and switch to FILL batching mode until FILL is completed 4 The unit will remain in...

Страница 13: ...oadcell no bin This means that the Smart Summing Box for the selected bin is not communicating Check for broken wires or loose connections or Smart Summing Box is not correctly configured or faulty lo...

Страница 14: ...ranty sets forth Buyer s sole and exclusive remedies for any defect in the goods The rights and obligation under this warranty may not be assigned or delegated to a third party by Buyer without the pr...

Отзывы: