background image

Installation and Operation Manual 

HL-10C Installation Manual Rev 2.0

 

3

 

Part Number MAN-000015

 

 

 

Description 

The HouseLink HL-10C provides a CAN bus interface to the CAN bus controller. 
 

The HouseLink HL-10C is designed

 

to be used with the BinTrac Bin Weighing system. One HouseLink HL-10C can be 

connected to one BinTrac indicator and can connect with a maximum of four bins. 

Installation 

 

1.  The HouseLink HL-10C should be mounted no more than 10 feet from the CAN bus controller. 
2.  Using a two-conductor cable (ordered separately), connect the GREEN wire from the Smart Summing Box to the 

+COM terminal in the HouseLink HL-10C and the White wire from the Smart Summing Box to the -COM terminal 
in the HouseLink HL-10C.  

3.  Connect the HouseLink HL-10C to the CAN bus controller by connecting the 

CAN (HI) 

to the 

CAN (HI) 

terminal 

and the 

CAN (LO) 

to 

CAN (LO)

 terminal of the CAN bus controller. 

4.  Finally, connect the 

24V (+) 

from the HouseLink HL-10C to the 

24V (+) 

of the CAN bus controller and the 

24V (-)

 

from the HouseLink HL-10C to the 

24V (-) 

of the CAN bus controller. 

 

 

 

       

        

Table 1

 

 
 
 
 
 
 
 
 
 
 
 

HL-10C Interface 

BinTrac Indicator 

(BINS Port) 

+COM (OUT) 

+ SIG (GREEN wire) 

-COM (OUT) 

- SIG (WHITE wire) 

HL-10C Interface 

CAN Bus Controller

 

CAN (HI) 

CAN (HI)

 

CAN (LO) 

CAN (LO) 

24V (+) 

24V (+) 

24V (-) 

24V (-) 

                      

Figure 1 

Содержание BinTrac HouseLink HL-10C

Страница 1: ...Installation and Operation Manual HL 10C Installation Manual Rev 2 0 Part Number MAN 000015 Installation and Operation Manual HouseLink HL 10C...

Страница 2: ...rdstar com Table of Contents Description 3 Installation 3 BinTrac Indicator Setup 4 LED Operation 4 CAN Bus Status LED 4 BinTrac Status LED 4 Testing and Calibration 5 Reset Test button 5 CAN Open Set...

Страница 3: ...separately connect the GREEN wire from the Smart Summing Box to the COM terminal in the HouseLink HL 10C and the White wire from the Smart Summing Box to the COM terminal in the HouseLink HL 10C 3 Con...

Страница 4: ...ral devices Access the SETUP menu on the BinTrac Indicator by pressing and holding the BIN key for until SETUP is displayed on the screen then release BIN key With SETUP displayed press the BIN key un...

Страница 5: ...the unit will output 25 full scale weight Test 3 Press the Reset Test button on the board three times and the unit will output 50 full scale weight Test 4 Press the Reset Test button on the board four...

Страница 6: ...ess CAN ID and if it is connected Utilize address 41 for bins 1 4 and address 42 for bins 5 8 Technical Installation Manual installation Silo weighing boxes Select the number of BinTrac bins enabled T...

Страница 7: ...lassic Setup The following two settings must be configured when using properly on the CAN bus controller to allow for accurate weight communication with the BinTrac system 1 Set Calibration value to s...

Страница 8: ...Specifications CAN Bus version Compatible with ISO 11898 STANDARDS Operating Temperature Range 40 C to 60 C 40 F to 140 F Operating Voltage Range 10 5 VDC to 27 0 VDC Humidity 5 to 95 non condensing E...

Страница 9: ...Installation and Operation Manual HL 10C Installation Manual Rev 2 0 Part Number MAN 000015 Wiring Diagram...

Отзывы: