Troubleshooting
Problem
Possible Causes
Likely Solutions
Tool will not start.
1. Cord not connected.
2. No power at outlet.
3. Tool’s thermal reset
breaker tripped (if equipped).
4. Internal damage or wear. (Carbon
brushes or switch, for example.)
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is unpowered,
turn off tool and check circuit breaker. If breaker
is tripped, make sure circuit is right capacity
for tool and circuit has no other loads.
3. Turn off tool and allow to cool.
Press reset button on tool.
4. Have technician service tool.
Tool operates slowly.
1. Excess pressure applied to workpiece.
2. Power being reduced by long or
small diameter extension cord.
1. Decrease pressure, allow tool to do the work.
2. Eliminate use of extension cord. If an extension
cord is needed, use one with the proper
diameter for its length and load. See
([WHQVLRQ
Cords
in
GROUNDING
section.
Performance
decreases over time.
Carbon brushes worn or damaged.
Have qualified technician replace brushes.
Excessive noise
or rattling.
Internal damage or wear. (Carbon brushes or
bearings, for example.)
Have technician service tool.
Overheating.
1. Forcing tool to work too fast.
2. Blocked motor housing vents.
3. Motor being strained by long or
small diameter extension cord.
1. Allow tool to work at its own rate.
2. Wear ANSI-approved safety goggles and NIOSH-
approved dust mask/respirator while blowing
dust out of motor using compressed air.
3. Eliminate use of extension cord. If an extension
cord is needed, use one with the proper
diameter for its length and load. See
([WHQVLRQ
Cords
in
GROUNDING
section.
Tool does not
grind, sand or
brush effectively.
1. Disc accessory may be loose on Spindle.
2. Disc accessory may be damaged,
worn or wrong type for the material.
1. Be sure disc accessory is of correct
dimension and Flange Arbor Nut is tight.
2. Check condition and type of disc accessory. Use
only proper type of disc accessory in good condition.
Follow all safety precautions whenever diagnosing or servicing
the tool. Disconnect power supply before service.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.