MAINTENANCE AND SERVICING
Procedures not specifically explained
in this manual must be performed
only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL
OPERATION: Make sure that the Power Switch is in
the Off-position and remove the Battery Pack before
performing any procedure in this section.
TO PREVENT SERIOUS INJURY FROM
TOOL FAILURE:
Do not use damaged equipment.
If abnormal noise or vibration occurs, have
the problem corrected before further use.
Cleaning, Maintenance,
and Lubrication
1.
BEFORE EACH USE,
inspect the general
condition of the tool. Check for:
• leaking, swollen, or cracked battery pack
• loose hardware
• misalignment or binding of moving parts
• cracked or broken parts
• damaged electrical wiring
• any other condition that may
affect its safe operation.
2.
AFTER USE,
wipe external surfaces
of the tool with clean cloth.
3. Disconnect battery pack and store battery pack,
charger, and tool in dry, indoor area out of
reach of children and away from metal objects
(i.e., paperclips, coins) to prevent shorting.
4.
Li-Ion BATTERY MUST BE RECYCLED OR
DISPOSED OF PROPERLY.
Do not short, incinerate or open battery.
5. Periodically, wear ANSI-approved safety goggles and
NIOSH-approved breathing protection and blow dust
out of the motor vents using dry compressed air.
6. Periodically wipe the Collet and cutting
bits with a light oil to prevent rust.