1.4  Proper usage  

 

The instrument or instrument components may only be used for the applications described in the manual or 
the technical description, and only in combination with the equipment, components, and devices of other 
manufacturers as far as this is recommended or permitted by Heraeus Electro-Nite. 

 

The instrument described has been developed, manufactured, tested, and the manual compiled in keeping 
with the relevant safety standards. Consequently, if the handling instructions and safety guidelines described 
for planning, installation, operation, and maintenance are adhered to, the instrument or device, under normal 
conditions, will not be a source of danger to property or life. 

1.5  RoHS regulations 

All electrical devices sold in the European market from the 1 July 2006 must fulfil the EU Directive 2002/95/EC, 
and RoHS 2 directive 2011/65/EU, on the Restriction of the use of certain Hazardous Substances in Electrical 
and Electronic Equipment (RoHS) as well as the national laws derived from it. According to the definition in 
Annex IB of the EU Directive 2012/19/EU WEEE, Heraeus Electro-Nite measuring instruments and analysis 
devices belong to category 9 - monitoring and control instruments. 
 
All Heraeus Electro-Nite instruments placed on the market after 1 July 2006 do not contain materials prohibited 
according to the RoHS directive. 
 
Affected parts and components are identified and adapted to the statutory requirements and other substances in 
those parts and components are utilized where necessary. The quality and usability of our devices are not 
affected. 
 
The adaptations are usually not visible, although adapted primary housing parts can show different surface color. 

1.6  WEEE regulations 

 

Heraeus Electro-Nite devices are exclusively for commercial use and may not be transferred to private use. 
Devices must be disposed of according to the national, statutory regulations for commercial electrical scrap. You 
must also follow the EU Directive WEEE regulations and their national conversion. If in doubt, ask your national 
importer or Heraeus Electro-Nite. 

All old Heraeus Electro-Nite devices can be deposited at Heraeus Electro-Nite premises, free of charge and 
using a certificated disposal company. The customer pays only for the carriage. 

 

 

According to the EU Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE), 
all electrical devices sold in the European market from the 13 August 2005 must be marked with 
a special symbol. This symbol (crossed out waste disposal receptacle with thick black bar 
underneath) indicates to the customer that the device must not be placed in household waste, 
but must be either deposited at a collection place for commercial scrap or returned to the 
manufacturer. 

Содержание Digilance V

Страница 1: ...HERAEUS Instruction and Operating Manual Temperature Measuring Unit Digilance V Document Version 1 01 Date of Issue 26 November 2018 Original instructions...

Страница 2: ......

Страница 3: ...Electro Nite This manual is copyrighted by Heraeus Electro Nite No part of this document may be reproduced transmitted transcribed stored in any retrieval system or translated into any language by any...

Страница 4: ...Page 2 of 21 Digilance V 26 November 2018 File name Digilance V_1 01 Version 1 01...

Страница 5: ...he Instrument 9 4 Standard Operation 10 4 1 First Use 10 4 2 Lance Installation 11 4 2 1 TC Wire Color Codes 11 4 3 Performing Measurements 12 4 3 1 Measurement Evaluation 12 4 4 Measurement History 1...

Страница 6: ...rating personnel who have been trained to work with automation equipment instruments or electronic devices and are conversant with the content of the manual in as far as it is connected with the actua...

Страница 7: ...Nite instruments placed on the market after 1 July 2006 do not contain materials prohibited according to the RoHS directive Affected parts and components are identified and adapted to the statutory re...

Страница 8: ...ep the battery out of the reach of children Never use a battery that appears to have suffered abuse Battery must be charged in appropriate charger only Never use a modified or damaged charger Store ba...

Страница 9: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency...

Страница 10: ...x which enables communication and data storage possibilities using Heraeus Electro Nite software The instrument also stores measurement results internally for downloading via the wireless interface 1...

Страница 11: ...ies ensure that the conductive packing does not touch or short circuit the battery connections if necessary cover the connections with insulating tape or material 3 3 Packaging the instrument Since th...

Страница 12: ...n Login o Instrument Info o Battery Info o Wireless Info optional Prior to using the instrument it is recommended to confirm the following instrument settings See Section Instrument Configuration Conf...

Страница 13: ...ument Assembly according to the diagram Conductive Shielding of the Thermocouple Extension Cable may not extending into the instrument housing This could create a short circuit of the electronic compo...

Страница 14: ...e Stop Difference 2 1 3 See Measurement Mode MULTI End Signal Duration 2 1 4 Controls the length of time that the Buzzer and Red Light will signal the end of the measurement Window 2 2 Temperature Res...

Страница 15: ...ible to enter Heat Numbers from the Main Measurement Display Set Place1 8 3 2 1 8 Configure the List of Eight Measurement Place Names Alphanumeric 10 digits Display Place 3 2 9 If set to Yes it is pos...

Страница 16: ...ed by pressing Charging Process Display Message LED Status Setup Charging Yellow Blinking Displayed when the Power Supply is initially connected to the device Charging Green Blinking Charge Level Indi...

Страница 17: ...ion Awake Time 4 1 Determines how long the instrument will remain awake after activity Set the values to ALWAYS to manually power the instrument On and Off Motion Sensitivity 4 2 Controls the accelero...

Страница 18: ...ITS90 1 3 L R Temperature Unit C F C F 1 4 Time 1 4 1 L R Time Format AM PM 24hr 24hr AM PM 1 4 2 Set Time 1 5 Date 1 5 1 L R Date Format DD MM YY MM DD YY DD MM YY MM DD YY 1 5 2 Set Date 2 Evaluatio...

Страница 19: ...erial Number 6 Service 6 1 Device Status Hardware Status Screen 6 2 Load Standard Parameters Yes No No No 6 3 Reset All Parameters Yes No No No 6 4 Temperature Offset 5 0 C to 5 0 C 0 C 0 C 7 A Admini...

Страница 20: ...tarting maintenance or installation make sure that you have sufficient protection against ESD Electronic devices can be destroyed by voltage and energy levels that are far below the level perceptible...

Страница 21: ...ging limit 0 C The charge current is used to heat the pack charging will initiate when the temperature is above the minimum limit Battery too hot Battery is too hot for charging Battery Temperature is...

Страница 22: ...s IPTS 48 IPTS 68 ITS 90 Thermocouple Accuracy Better than 1 C between 0 C and 50 C ambient temperature Display Resolution Configurable 1 or 0 1 Display Units C or F Data Storage 500 measurement resul...

Страница 23: ...rial number Description UCS Part Number Battery Pack Replacement 31600257 Rubber Boot 31600258 Standard Housing Replacement 31600259 Wireless Housing Replacement 31600260 Antenna Assembly 31600261 The...

Отзывы: