Fixing of the glass dome
Attention: The glass dome should only be fixed or
removed after having switched the unit off and
disconnected from the power pack. Please take care
that the flash tube and the modeling light won't be
damaged.
The glass dome is fixed by means of the three pre-
mounted springs. To do this, please tilt the glass dome
slightly and insert it into one of the three springs.
Then press the glass dome gently into the other two
springs until it has clicked in completely. For removing
the glass dome, please tilt it slightly again so that it will
slip out easily of the two fixing springs. Then gently loose
the glass dome from the remaining third spring and
remove it from the fixing device.
Assembly of accessories
Reflectors and softboxes
EH Pro Mini flash heads are equipped with a reflector
quick-change mechanism and can be used with the
whole range of Hensel reflectors and softboxes of the EH
line (adapter Ø: 10 cm).
For fixing reflectors or softboxes to the flash head, please
first of all open the holding clamps. To do this, please
tension lever
4
laterally as far as it will go against the
spring tension. While doing this, the holding clamps will
open. Now attach the accessory part even and precisely
to the unit. Please do not tilt. By releasing the lever, the
holding clamps will enclose the accessory part
completely.
For loosening the accessory, please hold the accessory
part (
Attention - it could be hot!
) tight and tension lever
4
again as described above.
In any case please make sure not to damage either the
flash tube or the modeling lamp (danger!).
Umbrellas and Softstar
An umbrella holder
5e
is integrated above the tilting head.
It allows the connection of various umbrellas or a Softstar
by using a strong gripping spring mechanism.
No screw required, which could cause damage to the
umbrella.
Glass dome
4: Reflector quick-
change mechanism
5e:
Umbrella holder
4