HENSEL-VISIT GmbH & Co. KG
Replace the Halogen Lamp for Modeling
Light
CAUTION
Risk of burns from reflector and flash unit
Heat which may cause burns develops at the head
during the flash process.
Before removing the reflector allow reflector
and flash unit to cool off.
CAUTION
Halogen lamp for modeling light can be damaged
When connecting the flash unit to the mains voltage
the halogen lamp of the modeling light can be
destroyed.
Check the type of the halogen lamp and the
fuse:
Mains voltage Halogen lamp Fuse
110 V
300 W / 110 V
4 A F
230 V
300 W / 230 V
2 A F
CAUTION
Glass safety dome may get damaged
When mounting a reflector the glass safety dome can
be damaged.
Do not touch the glass safety dome with the
reflector.
While mounting a reflector place the flash unit
on a stand.
Place the reflector evenly on the flash unit.
Make sure that all three holding claws are
inside the reflector.
When mounting a reflector hold it with one
hand.