background image

2

Henrad C80 FF and C95 FF - 

User's

Safety

Gas Safety (Installation and Use) Regulations, 1994,
Amendments 1996 or the rules in force.

 In your own

interest, and that of safety, it is the law that this boiler must
be installed by a CORGI registered installer, in accordance
with the above regulations.

It is essential that the instructions in this booklet are
strictly followed, for safe and economical operation of
the boiler.

Tampering with sealed components or incorrect use of
the boiler will invalidate the boiler guarantee.

CAUTION.

To avoid the possibility of injury during the installation,
servicing or cleaning of this appliance care should be taken
when handling edges of sheet steel components.

Electricity Supply

This appliance must be connected to the supply via a
double-pole switch, fused at 3 A.

Important Notes

1.

THIS APPLIANCE MUST NOT BE OPERATED WITHOUT
THE INNER FRONT SEALING PANEL BEING CORRECTLY FITTED.

2. Compartment Installations

If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.

Ventilation provided for boilers installed in compartments MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.

3.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT BE USED until the fault has been corrected by a
CORGI registered installer.

Escape of gas

Should a gas leak or fault be suspected contact your local gas
supplier without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains use a damp cloth and
mild detergent.

DO NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
CORGI registered installer.

IMPORTANT - DRAINING THE SYSTEM

It is

 not

 good practice to drain off radiators to decorate behind

them.  In the case of sealed system boilers, such as this      C80
FF, this will lower the system pressure AND MAY CAUSE THE
BOILER TO STOP WORKING.

Henrad C80 FF ............

G.C. Appliance No. 47 348 08

Henrad C95 FF ............

G.C. Appliance No. 47 348 09

CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning of

this appliance care should be taken when handling edges of sheet steel components.

Natural Gas Models Only

Minimum Clearances

The minimum clearances given below must be complied with in
order to maintain the safe running of the boiler and to facilitate
servicing.

Above the boiler -

160 mm (6 

1/4

")

At LH side of the boiler -

15 mm

(

5/8

")

At RH side of the boiler -

35 mm (1

 3/8

")

Underneath the boiler casing:

for service -

150 mm

(6")

Front of the boiler:

for service -

450 mm

(18")

Отзывы: