Henny Penny Wendy's MP94 Series Скачать руководство пользователя страница 3

Number of Drawers Programming 

1.  Turn unit off. 
2.  While holding in on the SET button and the number of drawers (i.e. 941 -> 1, 

942 -> 2, etc.) turn on the power. 

3.  Turn unit off and back on again.  Verify that the correct number of drawers is 

present in the power up messages. 

 

Error Codes 

1.  "E04" - control board too hot.  Possible problem:  Inadequate ventilation of 

louvers.  Unit placed in an area of intense heat. 

2.  "E06" - faulty temperature probe.  Possible problems: probe connections are 

loose, leads are cut or shorted, or probe is bad.  Check connections and wire 
schematic.  If problem not fixed, replace probe. 

3.  "E41" - EEProm memory scrambled.  Initialize board by pressing the up or 

down buttons. 

4.  "HI" - Software hi-limit.  Temperature in cabinet is too hot.  Possible problem:  

Relay failed in the closed position and heaters are locked on.  Make sure 
heater is not shorting out to chassis or this problem will reoccur. 