Henny Penny OFE- 290 Скачать руководство пользователя страница 15

                       Model OFE- 290

3-14.  PROGRAMMING
          (continued)

13.

After the end-of-cycle point is set, press and release the
FUNCTION button. “HEAD” flashes on the left side of the
display and a number shows on the right side of the display.
The number on the right, is the number of head of chicken to
be cooked at one time, when that product button is pressed.
The number can be changed by pressing the appropriate
product button.  The control can then accumulate the head
count (usage) of that product, based on counting the number
of Cook Cycles.

Another product can be programmed while in the program
mode by following these procedures:

Press and hold the SCAN button at any time while in the
Program Mode and the display will scroll “SELECT PROD-
UCT”.  Then press any of the product buttons, (1-0), and
now that product can be programmed.

14.

To program second interval, press and release the
SCAN button while in the Time Mode of the first mode.
“INT2” and “TIME” will flash on the left side of the display.
Then follow the steps above, starting with step 4.

3-15.   SPECIAL PROGRAM MODE

Review Usage

1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display.  As soon as
“REG PROGRAM” shows in the display, press and release
the FUNCTION button 1 time until “REVIEW USE” shows
in the display.

2.

“DAILY” shows in the display.  Press any of the product
buttons to view the usage of that product.  Press and hold the
FUNCTION button to exit Special Program mode.

Reset Usage

1.

Press and hold the FUNCTION button for two seconds until
“REG PROGRAM” shows in the display.  As soon as “REG
PROGRAM” shows in the display, press and release the
FUNCTION button 2 times until “RESET USE” shows in
display.

2.

When “CODE” shows in the display, press 1-3-5.  “DAILY
will show in the display, and press any of the Product buttons
to reset them to 0.

703

     3-15

Содержание OFE- 290

Страница 1: ...todraintheshorteningfromthefrypotintothefilterdrain pan Drain Interlock Switch Amicroswitchthatprovidesprotectionforthefrypotintheeventan operatorinadvertentlydrainstheshorteningfromthefrypotwhile themainswitchisinthePOWERposition theswitchisdesignedto automaticallyshutofftheheatwhenthedrainvalveisopened Shortening Mixing System Ashorteningmixingcapabilitytohelpensureshorteningisproperly mixedtopr...

Страница 2: ...to avoidburns FilterUnion Connects the filter to the filter pump and allows easy removal of the filteranddrainpan Fuses Aprotectivedevicewhichbreaksthecircuitwhenthecurrent exceeds the rated value 3 2 LID OPERATION Tocloselid 1 Lower the lid until latch comes into contact with the pot Toopenlid 1 Unlatchthefrontlidlatch 2 Lift up on handle to raise lid 3 3 MELT CYCLE If the shortening is below 185...

Страница 3: ...eremainingcooktime during Cook Cycles and also the shortening temperature on demand from the operator Heat Indicator Illuminateswheneverthecontrolcallsforheat whenshortening temperature has been reached the heat light goes off HITemperature Indicator The display reads HI if the shortening temperature is 40 F above thesetpoint DropIndicator The display reads DROP when the shortening has reached the...

Страница 4: ...erature thistemperatureextendstheshorteninglifeand minimizesthetimetoheattheshorteningforthenextCookCycle EXIT COOL button must be pressed to heat up to setpoint tem perature ALTHOUGHTHE DISPLAYWILLREAD COOL DURINGTHE STANDBYMODE THE SHORTEN ING IS HOTAND WILLCAUSE BURNS 3 4 SWITCHESAND INDICATORS Continued 3 4 504 TEMPERATURE BUTTON DIGITALDISPLAY Figure 3 2 ...

Страница 5: ...rtening be used in the open fryer Some low grade shortenings have a highmoisturecontentandwillcausefoamingandboilingover To avoid severe burns when pouring hot shortening into frypot wear gloves and take care to avoid splashing 2 The electric model requires 100 lbs 45 Kg of shortening The frypot has 2 level indicator lines inscribed on the rear wallofthefrypotwhichshowwhentheheatedshorteningisat t...

Страница 6: ...KG IS THE MAXIMUM AMOUNTOFPRODUCTPER FRYPOT FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RE SULT IN SHORTENINGOVERFLOWINGTHE FRYPOTWHICH COULD CAUSE SERIOUS BURNS PERSONALINJURY FIREAND OR PROPERTYDAMAGE 2 Turn the POWER PUMP switch to the POWER position and press the appropriate product button to select the amount of product to be cooked 3 Stir the shortening as it s heating up from a cold start Be s...

Страница 7: ... on the lid starting with the bottom rack to prevent damaged product Before loading product onto the racks lower the racks into the hot shortening to prevent the product sticking to the racks 6 Lower and latch the lid down and press the appropriate product button 7 At the end of the cycle an alarm sounds and the display shows DONE At this time press the appropriate product button 8 Unlatchandraise...

Страница 8: ... 9 5 kgs maximum orplaceproduct withextrememoisturecontent into racks WITH PROLONGED USE THE FLASHPOINT OF SHORTENING IS REDUCED DISCARD SHORT ENING IF IT SHOWS SIGNS OF EXCESSIVE SMOKING OR FOAMING SERIOUS BURNS PERSONALINJURY FIRE AND OR PROPERTY DAMAGE COULD RESULT 3 8 FILTERING The Henny Penny gas 6 head open fryer Model 290 must be INSTRUCTIONS cleaned and the shortening must be cleaned and p...

Страница 9: ...instructions causes splashing of shortening and could result in personal injury Surfaces of fryer and racks will be hot Use care when filtering to avoid getting burned 3 Remove cooking racks carrier and wipe bottom of lid Tilt lid out of the way to clean frypot 4 Pull drain handle towards you to open drain valve The handle should point straight out to the front of the fryer Use large white brush t...

Страница 10: ...HE SHORTENING IT S POSSIBLE THATTHE FILTER CONNECTIONATTHE UNION ON THE FILTER TUBE IS NOTTIGHTENED PROPERLY IFSO TURN OFFTHE PUMPAND USE PROTECTIVE CLOTH OR GLOVE WHEN TIGHTENING THE UNION THIS UNION WILLBE HOTAND SEVERE BURNS WILLRESULT 3 9 CHANGINGTHE FILTER The filter envelope should be changed after 10 12 filterings or ENVELOPE whenever it becomes clogged with crumbs Refer to KFC s Standards ...

Страница 11: ...t in the frypot it must be drained by slowly pulling the drain handle out towards you 3 Close the drain valve and discard the shortening 4 Raise lid remove the racks and carrier from lid and tilt lid back so that the lid won t interfere with cleaning 5 Refer to KFC s Standard s Library on cleaning instructions If the cleaning solution in the frypot starts to foam and boil over immediately turn the...

Страница 12: ...e following paragraphs provide step by step preventive maintenance procedures to be performed by the operator Procedure Frequency Filteringofshortening See KFC s Standards Library Changingofshortening See KFC s Standards Library Changingthefilterenvelope See KFC s Standards Library Cleaningthefrypot See KFC s Standards Library CleaningNylattrons Monthly seebelow Lubricatelidrollers Annually seebel...

Страница 13: ...Cycle and can be changed by pressing the appropriate numbers Ex Press 1 0 0 0 and 10 00 flashes on the right side of the display settingthestarttimeat10minutes 5 After setting the time press and release the FUNCTION button and INT1 and TEMP flashes on the left side of the display The right side shows the starting temperature and can be changed by pressing the appropriate numbers Ex Press 2 5 0 and...

Страница 14: ...an be toggled by pressing any of the product buttons l 0 YES means the alarm tone automatically stops after several beeps NO means some one must manually press the appropriate product button to stop the alarm tone 10 Repeat steps 9 and 10 for alarms 2 and 3 11 After alarm 3 is set press and release the FUNCTION button FILTER and CYCLES show on the left side of the display and the Filter Cycle valu...

Страница 15: ...ed 14 To program second interval press and release the SCAN button while in theTime Mode of the first mode INT2 and TIME willflashontheleftsideofthedisplay Then follow the steps above starting with step 4 3 15 SPECIAL PROGRAM MODE Review Usage 1 Press and hold the FUNCTION button for two seconds until REG PROGRAM shows in the display As soon as REG PROGRAM shows in the display press and release th...

Страница 16: ...e product buttons to toggle from GAS to ELEC or vice versa 4 Press and release the FUNCTION button twice and SPKR and VOL flashesinthedisplay Thevolumecan be changed from 01 to 10 10 being the loudest 5 Press and release the FUNCTION button 3 times and SPKR and FREQ willflashinthedisplay Thefrequency can be set from 100 to 2000 6 Press and release the FUNCTION button 10 times and INITIALIZE SYSTEM...

Страница 17: ...splay Also the LEDs over 1 and 3 flashes alternately 3 To test the heat circuit press and hold the 1 button 4 To test the pump system press and hold the 3 button Appliance Test Press and hold the FUNCTION button for two seconds until REG PROGRAM shows in the display As soon as REG PROGRAM shows in the display press and release the FUNCTION button 5 times until APPL TEST shows inthedisplay Withthep...

Страница 18: ... Press and release the FUNCTION button twice and MELT ON TIME and 100s shows alternately in thedisplay alongwiththelengthoftimetheheatison This should be set at 1700 and should not be changed until the factoryisconsulted 5 Press and release the FUNCTION button three times and COOL SET and POINT shows alternately in the display alongwiththetemperatureatwhichthecontrolexits the melt cycle This is se...

Отзывы: