Used to access the following:
• Advanced Product Settings
• Error Code Log
• Password Programming
• Alert Tone/Volume
• No. Of Cook Cycles Before Filter Is Suggested
• Automatic Filter Time
4
4..1
1 A
Ad
dvva
an
ncce
ed
d P
Prro
od
du
ucctt S
Se
ettttiin
ng
gss
1
1))
Press the temp and info hold and buttons until “LEVEL - 2” shows in the display,
followed by “ENTER CODE”.
2
2))
Enter code 1, 2, 3, 4 (first 4 product buttons). “PROD” and “COMP” show in the
displays.
3
3))
Press right ✓ button and “SELECT PRODUCT” “-P 1-” shows in the display.
4
4))
Use the left and right arrows to scroll through the 40 products, or press the
desired product button.
5
5))
Press right ✓ button and the product (ex: NUGGETS) shows in the left display,
and “MODIFY” “YES NO” shows in the right display. Press the ✓ button to
change this product, or press the “X” button to choose another product.
L
Lo
oa
ad
d C
Co
om
mp
pe
en
nssa
attiio
on
n,, L
Lo
oa
ad
d C
Co
om
mp
pe
en
nssa
attiio
on
n R
Re
effe
erre
en
ncce
e,, F
Fu
ullll H
He
ea
att,, P
PC
C F
Fa
acctto
orr
6
6))
If ✓ button was pressed, “LD COMP” shows in the display along with the load
compensation value. This automatically adjusts the time to account for the size
and temperature of the cooking load. Press the product buttons to change this
value of 0 to 20.
7
7))
Press the down arrow until “LCMP REF” shows in the display along with the
load compensation average temperature. (if load compensation is set to “OFF”,
then “_ _ _” shows in display and setting cannot be programmed.) This is the
average cooking temperature for each product. The timer speeds up at
temperatures above this setting and slows down at temperatures below this
setting. Press the product buttons to change this value.
8
8))
Press the down arrow until “FULL HT” shows in the display along with the full
heat value in seconds, which means the heat is on as soon as a timer button is
pressed, for the programmed length of time. Press the product buttons to
change this value of 0 to 90 seconds.
9
9))
Press the down arrow until “PC FACTOR” shows in the display along with the
proportional temperature, which helps to keep the oil from over-shooting the set-
point temperature. Press the product buttons to change this value of 0 to 50
degrees.
Содержание LVE-202
Страница 2: ......
Страница 6: ...Contents iv...
Страница 8: ...Preface vi...
Страница 24: ...Info Filter Temp Button Stats 12...
Страница 32: ...Level 2 Programming 20...
Страница 50: ...Maintenance 38 NOTE Oil temp must be 380 F 193 C to perform this check...
Страница 88: ...Maintenance 76...
Страница 90: ......
Страница 91: ......
Страница 92: ...Wiring Diagrams 155...
Страница 93: ...Wiring Diagrams 156...
Страница 94: ...Wiring Diagrams 157...
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ...Wiring Diagrams 161...
Страница 99: ...Wiring Diagrams 162...
Страница 100: ...Wiring Diagrams 163...
Страница 101: ...Wiring Diagrams 164...
Страница 102: ...Wiring Diagrams 165...
Страница 103: ...Wiring Diagrams 166...
Страница 104: ...Wiring Diagrams 167...
Страница 105: ...Wiring Diagrams 168...
Страница 106: ...Wiring Diagrams 169...
Страница 107: ...Wiring Diagrams 170...
Страница 108: ...Wiring Diagrams 171...
Страница 109: ...Wiring Diagrams 172...
Страница 111: ...Wiring Diagrams 174...
Страница 112: ...Wiring Diagrams 175 Figure 10 1 Plumbing Diagram...
Страница 113: ...Wiring Diagrams 176...
Страница 114: ...blank page...