Henny Penny KVE-071 Скачать руководство пользователя страница 39

July 2014 

32 

 

 

an alarm time in the right 

 

1.

 

Press and release ▼ button and “TEMP” shows in display,

 along 

with preset temperature on the right side of the display. 

 

Press the product buttons 

 to change 

the temperature. The temperature range is 190°F (88°C) to 380°F 

(193°C). 

 

Cook ID Change

 

 

2.

 

Press 

▼ 

button until “COOK ID” shows in the display 

along with the product ID. For example, NUG would be the 

ID for nuggets. Use the product buttons to change the ID, 

following the same procedure as Step 6 above. 

 

Alarms (Duty 1 & 2)

 

 

3.

 

Press ▼ button until “DUTY 1” shows in the left display,

 and 

splay. Press the product buttons 

to set an alarm. 

 

Ex., If a Cook Cycle was set at 3 minutes, and an alarm was to go 

off after 30 seconds into the Cook Cycle, “0:30” would be set in 

the display at this time. When the timer counts down to 2:30 the 

alarm sounds. 

 

After the alarm time is set, press ▼ button and “DUTY 2” shows 

in the display, and a second alarm can be programmed. 

 

Quality Time

 

4.

 

Press ▼ button until QUAL TMR is displayed along with preset 

holding time. Press product buttons 

 

to adjust holding time, up to 2 hours, 59 minutes. 

 

AIF Disable

 

5.

 

Press ▼ button until “AIF DISABLE” shows in the display 

along with “YES” or “NO”. Using ◄ and

 

► buttons change 

the display to “YES” if that product is to not be included in the 

automatic intermittent filtration operation, or “NO” if it is to be 

included. 

 

Assign Button

 

 

6.

 

Press ▼ button until “ASSIGN BTN” shows in the display,

 along 

with the product (ex: NUGGETS). If this product already has a 

product button assigned to it, that LED will be lit. To assign other 

product buttons to that product, press and hold the product button 

for 3 seconds and that LED stays lit. To remove a product from a 

button, press and hold the product button with a lit LED and the 

LED goes out. 

4-1

 

MODIFYING 

PRODUCT SETTINGS 

(CONT.)

 

Содержание KVE-071

Страница 1: ...OPERATOR S M A N U A L SPLIT FULL VAT ELECTRIC OPEN FRYER MODEL KVE 071 KVE 072 KVE 073 KVE 074 Read instructions before operating the appliance REGISTER WARRANTY ONLINE AT WWW HENNYPENN Y COM...

Страница 2: ......

Страница 3: ...in relief Install the provided power cord with the ground wire dimensioned to fail last If the supplied power cord or an existing one becomes damaged do not use it rather replace it with a known good...

Страница 4: ......

Страница 5: ...Up Procedures 16 3 5 Cooking with Dedicated Display 17 3 6 Cooking with Multi Product Display 18 3 7 Change from Breakfast to Lunch Lunch to Breakfast 18 3 8 Change from Multi Product Display to Dedi...

Страница 6: ...Clock 33 4 3 Deep Clean Mode 34 4 4 Fryer Setup 38 Section 5 LEVEL 2 PROGRAMMING 39 5 1 Advanced Product Settings 39 5 2 E Log error code log 40 5 3 Password 41 5 4 Alert Tone 41 5 5 Filter After 42...

Страница 7: ...roducts as needed in order to comply To continue compliance with these directives this unit must not be disposed as unsorted municipal waste For proper disposal please contact your nearest Henny Penny...

Страница 8: ...ING CAUTION or NOTICE are used Their usage is described as follows SAFETY ALERT SYMBOL is used with DANGER WARNING or CAUTION which indicates a personal injury type hazard NOTICE is used to highlight...

Страница 9: ...ctronic Equipment WEEE Symbol OR Shock Hazard Symbols OR Hot Surface Symbols Shows direction to turn the red handle to open the drain valve to drain oil from vat Shows direction to turn the yellow han...

Страница 10: ...d in the presence of the delivery agent and signed prior to his or her departure 1 Cut and remove the metal bands from the carton 2 Remove the carton lid and lift the main carton off the fryer 3 Remov...

Страница 11: ...s service Keep in mind the best efficiency will be obtained by a straight line operation i e raw in one side and finished out the other side Order assembly can be moved away with only a slight loss of...

Страница 12: ...to local electrical codes for correct ground ing earthing procedures or in absence of local codes with The National Electrical Code ANSI NFPA No 70 the current edition In Canada all electrical connect...

Страница 13: ...available in the rear fryer frame for securing the cable restraint to the fryer The cable restraint does not prevent the fryer from tipping DRYWALL CONSTRUCTION Secure I bolt to a building stud Do not...

Страница 14: ...July 2014 8a Casters adjustable up to 1 562 in 40mm 2 9a DIMENSIONS...

Страница 15: ...6 425 in 1180 mm Adjustable Up 800 in 20 mm Weight 243 lbs 110 kg Crated Width 21 70 in 551 mm Depth 36 13 in 918 mm Height 53 60 in 1361 mm Weight 298 lbs 135 kg Electrical Volts 220 380 Phase 3 Hert...

Страница 16: ...July 2014 9 3 1 OPERATING COMPONENTS 1 2 3 4 5 6 7 8 9 Figure 3 1 10 11 12 13 14 15 16 Figure 3 2 SECTION 3 OPERATION...

Страница 17: ...e Program Mode shows the temperature of the oil by pressing shows error codes also displays in several lan guages 3 1 5 During normal operation press this button to start and stop cook cycles for the...

Страница 18: ...used for button press to view the following tempera ture stats a actual oil temperature in each vat b setpoint temperature for each vat 3 1 13 Used in the Programming Modes also used for but ton press...

Страница 19: ...itches for each well 3 4 4 Vat Covers Covers the vat when not in use 3 4 5 Filter Valve Handles Yellow handles open close filter valve when pumping oil into vat 3 4 3 4 6 Drain Valve Handles 7 Purge H...

Страница 20: ...KA Press to continue with the other set up items which include ZONE USA EUROPE CHINA OTHER TEMP FORMAT F or C TIME FORMAT 12 HR or 24 HR ENTER TIME Time of day use product buttons to change ENTER TIME...

Страница 21: ...e 2 Figure 3 Wear gloves to avoid severe burns when pouring hot oil into vat Oil andall metal parts that are in contact with the oil are extremely hot and take care to avoid splashing 2 Oil Capacities...

Страница 22: ...5 seconds The controlthen shows EXIT MELT YES NO Press buttonfor YES and vat heats continuously until the set point temperature is reached Do not bypass the Melt Cycle unless enough oil has melted to...

Страница 23: ...5 Press the timer button under PULL to stop the alarm and lift basket from vat 6 If a Quality Timer hold timer has been programmed the hold time starts automatically when the user presses the timer b...

Страница 24: ...mer hold time has been programmed the display shows the timer counting down see step 6 Section 3 5 This procedure is basically changing the product being cooked in a vat with a dedicated display Break...

Страница 25: ...o the Multi product Display Mode Only products programmed for this set point temperature will be able to be selected for cooking 1 Press a product button for ex 2 The display shows FR FRIES if the set...

Страница 26: ...display shows SKIM VAT followed by CONFIRM YES NO Once the crumbs are skimmed off the top of the oil press button for YES and display shows OPEN RED DRAIN VALVE Turn red drain handle to open drain and...

Страница 27: ...July 2014 20 NO Make sure vat is full and then press button...

Страница 28: ...Display shows OPEN BLACK PURGE VALVE followed by CONFIRM NOTE This prompt only displays if the unit is enabled for Solid Shortening in the settings Liquid shortening is the preferred oil IMPORTANT Lea...

Страница 29: ...FILTER 4 Press and release button and display shows 2 MAINT FILTER 5 Press button for YES and display shows DRAIN PAN READY Make sure drain pan and cover are in place and press button Display shows M...

Страница 30: ...DRAIN Turn red drain handle to close drain and then display shows ISPOTFILLED followedby YESNO 12 Once vat is full press buttonand CLOSERETURNVALVE followed by CONFIRM shows in display Using yellow h...

Страница 31: ...Close the black purge handle and then press button Check the level of oil in vat and add fresh if necessary until oil is level with the topindicatorlineonrearwallofvat 19 Press toturnonheatandcontinue...

Страница 32: ...n could be hot Use protective cloth or glove or severe burns could result If the filter pan is moved while full of oil use care to prevent splashing or burns could result 2 Lift the pan cover from the...

Страница 33: ...5 Figure 6 Figure 7 5 Pull the filter pad from the pan and discard pad Figure 5 6 Remove the bottom screen from pan and clean thoroughly with soap and water Rinse thoroughly with hot water Figure 6 7...

Страница 34: ...sh the filter pan assembly back underneath the fryer making sure the filter tube on the pan makes a good connection with the fitting underneath the fryer Figure 9 10 Make sure the drain pan stop is en...

Страница 35: ...ats modes the controls revert back to normal operation Cook Cycles Remaining before Filtering 1 Press and release either or and the left display shows COOKS REMAIN and the right display shows the numb...

Страница 36: ...X button to exit from the Information Mode 1 FILTER STATS Press button to select Filter Stats and then press and to select the day you want to view the stats Then press or buttons to view the fol lowi...

Страница 37: ...Time and day last Cook Cycle was started STARTED 10 25A AUG 11 Actual Elapsed cook Time Real seconds ACTUAL TIME 7 38 Programmed cook Time PROG TIME 3 00 Max Temp during Cook Cycle MAX TEMP 327 F Min...

Страница 38: ...change this product or press the X button to choose another product 6 If button was pressed press and release a product button and the flashing letter changes to the first letter under the product bu...

Страница 39: ...o 2 30 the alarm sounds After the alarm time is set press button and DUTY 2 shows in the display and a second alarm can be programmed Quality Time 4 Press button until QUAL TMR is displayed along with...

Страница 40: ...grammed for Satur days and a final set of four blocking periods may be programmed for Sundays 1 Press and hold and buttons until LEVEL 1 shows in the display followed by ENTER CODE 2 Enter code 1 2 3...

Страница 41: ...e right side X button to exit out of AIF Clock programming mode Put on protective gear Be sure to use all approved safety equipment including apron face shield and gloves Never begin Deep Clean proces...

Страница 42: ...in 25 mm above the top fill line Then press button and display shows START CLEAN YES NO 9 Press button display shows CLEANING and a countdown timer Heat regulates to 195 F 91 C for this step for one...

Страница 43: ...nts This produces scratches on the surface of the element causing breading to stick and burn Do not use steel wool other abrasive cleaners or cleaners sanitizers contain ing chlorine bromine iodine or...

Страница 44: ...ES NO To avoid burns make sure all water and cleaning solution has been removed from the vat 18 Pull drain pan from under fryer and empty using the 1 2 gal 2 liter pitcher and pouring it into a heat r...

Страница 45: ...OL PORTUG DEUTSCHE SVEN SKA Press to continue with the other set up items which include ZONE USA EUROPE CHINA OTHER TEMP FORMAT o F or o C TIME FORMAT 12 HR OR 24 HR ENTER TIME Time of day use product...

Страница 46: ...utton to change this product or press the X button to choose another product Load Compensation Load Compensation Reference Full Heat PC Factor 6 If button was pressed LD COMP shows in the display alon...

Страница 47: ...urn to the PRODUCT SELECTN step Press X button a second time to exit PROD COMP mode 1 Press and hold and buttons until LEVEL 2 shows in the display followed by ENTER CODE 2 Enter code 1 2 3 4 first 4...

Страница 48: ...utton and MODIFY YES NO shows in the display Press right button to change the 4 digit password for the Set Up Mode using the product buttons 6 Once new password is entered CONFIRM PASSWORD shows in th...

Страница 49: ...controls suggest filtering 0 to 99 4 Once set press button to confirm This is the amount of time fryer sits idle until filter is suggested 1 Press and hold and buttons until LEVEL 2 shows in the displ...

Страница 50: ...22 and enter 3 levels of programming 2 Use the UP DWN button loop menu to select Special Programming 3 Using the UP DWN button Loop menu select SP 17 User Polish Enabled Then select YES 4 Set the poli...

Страница 51: ...error E 22 All power cords not plugged in Unit has 2 power cords make sure both are plugged in have heat circuit checked Control error code E 10 Open high limit circuit Allow heating elements to cool...

Страница 52: ...e Filter paper or pad clogged Tighten all filter line connections Change filter paper or pad Bubbles in oil during entire filteringprocess Filter pan not completely engaged Filter pan clogged Damaged...

Страница 53: ...witch to OFF position then turn switch back toON if display shows E 6A the temperature probe should be checked E 6B Temperature probe shorted Turn switch to OFF position then turn switch back to ON if...

Страница 54: ...if E 47 persists have the PC board replaced E 48 Input system error Turn switch to OFF then back to ON have control PC board replaced if E 48 persists E 54C Temperature input error Turn switch to OFF...

Страница 55: ......

Страница 56: ...nny Corporation P O Box 60 Eaton OH 45320 1 937 456 8400 1 937 456 8402 Fax Toll free in USA 1 800 417 8417 1 800 417 8434 Fax FM05 257 A Henny Penny Corp Eaton Ohio 45320 Revised 11 11 20 www hennype...

Отзывы: