Explanations regarding maintenance
36
Maintenance instructions
9 Explanations regarding maintenance
9.1 Water connection
9.1.1 Clean fine sieve
Fine sieve are installed at the drinking water and softened drinking
water connections.
Water supply line disconnected from the supply network
1. Loosen the screw connection of the line
Drinking water
and pull it
off.
Check the seal.
Replace damaged seal.
2. Remove the fine sieve.
3. Clean limescale deposits with a soft brush and vinegar or citric acid.
4. Rinse the fine sieve with clear water.
5. Insert fine sieve.
6. Put on the screw connection and screw it tight.
Insert seal.
7. Fine sieve on the line
Softened drinking water
also clean.
9.2 Cleaning and descaling the unit
9.2.1 Clean unit
INFORMATION
Clean the unit according to the operating instructions.
9.2.2 Removing calcium deposits from the unit
Prerequisite
Cooking chamber temperature less than 40 °C (104 °F)
Cooking chamber cleaned
1. Open the air diverter.
2. Spray commercially available descaler into the cooking chamber.
3. Allow to act for 30 minutes.
4. Rinse the cooking chamber thoroughly.
5. Examine the cooking chamber for any remaining calcium deposits.
6. If necessary, repeat the decalcification.
7. Open the cooking chamber door and leave it ajar until the unit is
used again.
This extends the service life of the door seal.
No moisture builds up in the cooking chamber.
FM06-140
Содержание FlexFusion ELECTRIC SPACESAVER PLUS TEAM
Страница 2: ...2 Maintenance instructions...
Страница 35: ...Performing maintenance 35 Maintenance instructions Notes and remarks FM06 140...
Страница 42: ...Acceptance of maintenance 42 Maintenance instructions FM06 140...
Страница 43: ......
Страница 44: ...FM06 140 Henny Penny Corp Eaton Ohio 45320 Revised 2 7 2022...