6
Connecting the unit
Making the wastewater connection
36
Cleaning system
Sewer system connection
Manual cleaning system
Pictogram on control panel
Connecting the wastewater line permanently
Connecting the wastewater line permanently
a Wastewater discharge from
unit
d Wastewater system trap
b Wastewater line
e Pipe clamp
c Wastewater system
f Vacuum breaker valve
NOTICE
If a waste trap is installed in the wastewater system, a vacuum breaker
must be installed in the wastewater line.
Polypropylene (PP) pipes and elbows
▪
Heat-
resistant to 95 °C
(203°F)
▪
Nominal diameter 50 mm (2in)
▪
Maximum pipe length 1.0 m (39in)
a) Install wastewater line up to connection to the sewer system
.
b) Secure the wastewater line with clamps.
c) Pour tap water into the wastewater trap on the unit.
6.6.3
Requirement