INSTALLATION MANUAL
FlexFuison
® GOLD
ELECTRIC COMBI
FGE-615
FGE-621
FGE-115
FGE-121
FGE-215
FGE-221
Страница 1: ...INSTALLATION MANUAL FlexFuison GOLD ELECTRIC COMBI FGE 615 FGE 621 FGE 115 FGE 121 FGE 215 FGE 221...
Страница 2: ...ansporting the unit 14 4 1 Transport information 14 4 2 Transporting to the installation site 14 4 2 1 Transporting on a pallet 15 4 2 2 Transporting without a pallet 15 4 2 3 Transporting by raising...
Страница 3: ...ting menu 31 6 4 2 Changing the basic settings 31 6 5 Making the water connection 32 6 5 1 Information regarding the water connection 32 6 5 2 Connecting hard and soft water 32 6 5 3 Connecting soft w...
Страница 4: ...nts from the manufacturer Pass on the installation manual to any subsequent operator of the unit The target group for the installation manual is trained technical personnel that is familiar with insta...
Страница 5: ...an cause material damage NOTICE Information Notes for better understanding and operation of the unit Symbol sign Meaning Listing of information Action steps which can be performed in any sequence 1 2...
Страница 6: ...in commercial kitchens This unit is certified in the following Warranty The warranty is void and safety is no longer assured in the event of Modifications or technical changes to the unit Improper use...
Страница 7: ...arts Risk of fire from combustible surfaces Observe general fire prevention regulations Risk of property damage and personal injury from lack of organizational measures Identify hazard areas when tran...
Страница 8: ...nsure that the electrical system is earthed by a protective earthing conductor Note the information on the nameplate Risk of electric shock from live components Prior to working on the electrical syst...
Страница 9: ...y a Tray rack k Base frame optional b Insulated window l Equipment foot c Door handle m Operating control d Cooking zone door n Housing e Tray rack trolley optional o Air intake connection fitting f S...
Страница 10: ...ap optional j Hand shower optional FlexFusion with tray trolley a Tray rack k Equipment leg b Insulated window l Equipment foot c Door handle m Operating control d Cooking zone door n Housing e Guide...
Страница 11: ...tion of the unit 3 Planning drawing 11 h Guide rail left r Connection optional i USB port covered s Protective cap optional j Hand shower Planning drawing Combisteamer sizes 6 and 10 Combisteamer size...
Страница 12: ...2 1000 x 800 x 1060 39 x 31 x 42 1075 x 813 x 1722 42 x 32 x 68 1075 x 813 x 1722 42 x 32 x 68 Packaged unit Length x width x height mm in 1080 x 960 x 1020 39 x 38 x 40 1080 x 960 x 1020 39 x 38 x 40...
Страница 13: ...ion Type of water Softened tap water cold Carbonate hardness CaCO3 mmol l 1 5 Chloride Cl mg l 50 Iron Fe mg l 0 1 Connection pressure hPa bar 200 600 2 6 Type of connection R male thread Hard water c...
Страница 14: ...are large enough Removing the packaging reduces the clear width required Equipment and connection data 12 Transporting to the installation site WARNING Risk of property damage and personnel injury fro...
Страница 15: ...ite Transporting without a pallet SAFETY INSTRUCTIONS Risk of physical damage from improper lifting of the unit a Lift size 6 and size 10 units only with the aid of wooden beams placed underneath Unit...
Страница 16: ...t a pallet d Move the unit to the installation site Unit size 20 Packaging removed except for the pallet a Move the pallet truck under the guide rails of the unit from the right b Lift the unit off th...
Страница 17: ...revent tipping c Carefully lift the unit onto the pallet Unpacking the unit WARNING Risk of injury from sharp edges Wear protective gloves NOTICE When unpacking the unit inspect it for transport damag...
Страница 18: ...s a Observe applicable regional fire prevention regulations SAFETY INSTRUCTIONS Risk of physical damage from overheating of the unit a Do not set up the unit close to heat sources Lifting the unit off...
Страница 19: ...loor must carry the weight of the unit a Lift the unit with the pallet truck b Move the unit to the installation site c Place the unit on the floor d Set up the unit in accordance with the planning dr...
Страница 20: ...t b Place the unit over the stud bolts on the work surface WARNING Risk of burns from missing stickers a Attach stickers if the upper insertion rails are higher than 1 60 m 63in Attach warning sign re...
Страница 21: ...b Screw the equipment legs in or out to level the unit Aligning floor standing units NOTICE The tray trolley is needed to align a floor standing unit Prepare the tray trolley a Screw the equipment le...
Страница 22: ...Retract the tray trolley f Level the support rails g Push the tray trolley against the unit until it stops h Remove the push handle i Close the cooking zone door The unit is aligned correctly Minimum...
Страница 23: ...he left 500 mm 20in to heat sources baking ovens so that the cooling air for the unit is not heated Left and right one length of the hand shower so that no water can be sprayed into the hot deep fat f...
Страница 24: ...erate the unit with the housing open WARNING Risk of injury from sharp edges a Wear protective gloves CAUTION Risk of physical damage from damage to the lines a Remove and attach housing components ca...
Страница 25: ...make sure that no lines are squeezed a Insert the top edge of the side panel SAFETY INSTRUCTIONS Risk of physical damage from a loose side panel a The side panel must be in contact with the unit on a...
Страница 26: ...3NPE AC 50 60Hz Voltage V 200 Connected load kW 9 7 16 3 14 7 25 5 29 4 50 9 Fusing A 35 50 50 80 100 180 Voltage V 208 Connected load kW 10 2 17 4 15 7 27 3 31 4 54 6 Fusing A 35 50 50 80 100 180 Vo...
Страница 27: ...ns The unit can be connected to a residual current protective device The residual current protective device must incorporate a residual current protective switch of type B RCD Type B in order to detec...
Страница 28: ...socket must be readily accessible so that the unit can be disconnected from the electric mains at any time Connecting the electric power cable to the unit Electrical connection terminal diagram in th...
Страница 29: ...to the unit matches the information on the nameplate Housing open Electric power cable sufficiently long a Insert the electric power cable into the unit through the cable gland b Connect the electric...
Страница 30: ...ntry for the electric power cable b Bring the connection cable to the connection terminals c Attach the connection cable in accordance with the terminal diagram d Secure the connection cable with cabl...
Страница 31: ...d Changing the basic settings a Press the START STOP button The left display flashes the first number of the basic setting refer to the list of basic settings The centre display shows OPt The right di...
Страница 32: ...0 No 1 Yes Yes Power limited to 80 for special applications Power optimizing system connected 5 0 0 No 1 Yes If the power optimizing system is connected Yes must be selected for the unit to heat Makin...
Страница 33: ...the water quality complies with the equipment and connection data SAFETY INSTRUCTIONS Hygiene risk from contaminated drinking water a The connection to the drinking water supply must be equipped with...
Страница 34: ...is available at the installation site the hard water connection fitting and the soft water connection fitting must be connected by means of a T piece Soft water connection twice a Soft water tap e Har...
Страница 35: ...nvolved Identifying the cleaning system FlexFusion Gold units can be equipped with either an automatic or manual cleaning system The pictogram on the control panel shows which cleaning system is insta...
Страница 36: ...b Wastewater line e Pipe clamp c Wastewater system f Vacuum breaker valve NOTICE If a waste trap is installed in the wastewater system a vacuum breaker must be installed in the wastewater line Polypr...
Страница 37: ...ect only the discharge funnel if a wastewater trap is installed in the wastewater system Polypropylene PP pipes elbows discharge funnel and waste trap Heat resistant to 95 C 203 F Nominal diameter 50...
Страница 38: ...a Do not incorporate the exhaust air line directly into an exhaust air system CAUTION Risk of corrosion damage from condensate a Install the exhaust air line such that condensate cannot collect Flexi...
Страница 39: ..._________________________________________ Item Nr _____________________________ if listed Obvious damage to the unit What and where ____________________________________________________________________...
Страница 40: ...Yes No Wastewater connection made properly On site waste trap Vacuum breaker Funnel discharge Wastewater pipe dimension ____________________ mm in Exhaust air connection Yes No Set up under exhaust h...
Страница 41: ...tion was provided by Company Installer City date Signature Wastewater installation was provided by Company Installer City date Signature Exhaust air connection was provided by Company Installer City d...
Страница 42: ...nny Penny Corporation P O Box 60 Eaton OH 45320 1 937 456 8400 1 937 456 8402 Fax Toll free in USA 1 800 417 8417 1 800 417 8434 Fax www hennypenny com Henny Penny Corp Eaton Ohio 45320 Revised 2 19 1...