![Henny Penny CMC-103 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/henny-penny/cmc-103/cmc-103_operators-manual_2124252016.webp)
Model CMC/CMR-103,104,105,106,107
3-4. CLEANING
Every 3 Months:
(Continued)
1. Remove all electrical power supplied to the unit by unplugging
the power cord from the wall, or by turning off the wall circuit
breaker.
2. Remove all product from the unit.
3. Remove the riser and trays from the unit and clean with
soap and water at a sink.
4. Clean interior surfaces with a soft cloth, soap and water.
Do not use steel wool, other abrasive cleaners or
cleaners/sanitizers containing chlorine, bromine, iodine
or ammonia chemicals, as these will deteriorate the
stainless steel, and glass material, and shorten the life of
the unit.
Do not use a water jet (pressure sprayer) to clean the
unit, or component failure could result.
5. Clean around light fixtures with a soft, damp cloth.
6. Reconnect the electrical power, and unit is now ready for
operation.
If the power cord is damaged, have a qualified service
technician replace it to prevent electrical shock or
property damage.
303
3-4
Содержание CMC-103
Страница 10: ...Model CMC CMR 103 104 105 106 107 2 9 CUT OUT DIMENSIONS FOR DRYBASE OR TABLE INSTALLATION 303 2 5...
Страница 14: ...Model CMC CMR 103 104 105 106 107 Figure 3 1 3 2 1 4 5 303 3 2 3 2 OPERATING CONTROLS Continued...
Страница 20: ...Model CMC CMR 103 104 105 106 107 1002 3 8 DIAGRAM FOR CMC MODEL...
Страница 21: ...Model CMC CMR 103 104 105 106 107 DIAGRAM FOR CMR MODEL 3 9 1002...
Страница 22: ...Model CMC CMR 103 104 105 106 107 230V 50Hz 1ph CE 1002 3 10...
Страница 28: ......