WATER SUPPLY

The Combi-Steamer should only be connected to a cold water supply which meets the quality requirements by the
EPA on drinking water. Soft water must be at least 5 or 6 grains.

The recommended water supply pressure is 44 psi, but 22 to 87 psi will work.

The water connection is done on a 3/4” NPT thread fitting, and a manual shut off valve must be installed between
the main cold water supply and the units supply line.

NOTE:

A check valve is built into the unit to prevent backflow.

DRAIN CONNECTION

The Combi-Steamer is to be installed to comply with the applicable Federal, State, or local plumbing codes.

The unit has an integrated vented drain system which acts as a reverse flow check valve, so it may be connected
directly with a P-trap to the drain system.

Installation – Electric Units 

(continued)

A minimum water conductivity of 20 micro Siemens is required for proper operation.  If below this figure
the steam generator will over-fill.

The drain must have a constant slope and a diameter of 2 inches over its entire length to ensure sufficient
discharge during Auto Flush from the steam generator, which is 3/4 quarts per second.

The drain must be steam temperature resistant pipe, which average drain temperature is 150°F (65°C).
No hose should be used.

Should the water pressure exceed 87 psi, a pressure regulator must be installed into the supply line or
damage to the unit could result.

Содержание B-1020

Страница 1: ...e Back Side CSB CSM CSL 6 10 1020 6 150mm 2 50mm 2 50mm NOTE 14 350mm is recommended at the left side of the unit for service purposes Place the combi steamer on an original Henny Penny stand or on a...

Страница 2: ...shing oven racks into unit The oven rack must be positioned vertically in the unit not tilting For minor unevenness in floor the oven rack can be leveled using the optional leveling device If necessar...

Страница 3: ...70 1990 NOTE All connections must comply with the oven data plate A separate fused disconnect switch or circuit breaker not furnished MUST be installed in the electrical supply line FOR EACH OVEN NOTE...

Страница 4: ...or local plumbing codes The unit has an integrated vented drain system which acts as a reverse flow check valve so it may be connected directly with a P trap to the drain system Installation Electric...

Страница 5: ...ill provide easy loading and unloading without interfering with the final assembly of food orders Installation Gas Units Do Not puncture the cabinet with any objects such as drills or screws as electr...

Страница 6: ...version The stacked version kit comprises two different draft hoods one with a single outlet and the second with a double outlet A flue riser completes the stacked version flue assembly Fix the singl...

Страница 7: ...n integrated vented drain system which acts as a reverse flow check valve so it may be connected directly with a P trap to the drain system Should the water pressure exceed 87 psi a pressure regulator...

Страница 8: ...all electrical connections are to be made in accordance with the CAN CGA B149 1 or 2 installation code and or local code and the Canadian electrical code Part 1 CSA C22 1 Before connecting incoming p...

Страница 9: ...reates double bends causing work fatigue failure of the fittings In all installations where self draining is not necessary connect metal hose in a vertical loop DO NOT CONNECT METAL HOSE HORIZONTALLY...

Страница 10: ...nces in the kitchen are on high flame The mini mum and maximum incoming line flow pressures should be as follows Natural 7 11 water column Propane 11 water column Installation Gas Units continued Neve...

Страница 11: ...be taken by installing a gas pressure gauge on the front of the unit s main gas valves test port This should be done with all gas appliances in operation on the same gas supply line Should the manifol...

Отзывы: