![Henny Penny AHC-990 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/henny-penny/ahc-990/ahc-990_technical-manual_2124124015.webp)
Model AHC-990/993
2-1
The Tech Mode and Stats Mode in the Level 2 Programming,
have information that could help in troubleshooting a problem
with the unit.
Press and hold until “L-2 LEVEL 2”, followed by,
“CLOCK SET”, shows in display.
Press 3 times and “TECH”, followed by, “ENTER
CODE” shows in display.
Enter code,
to access
the following items: (Use hidden buttons, see Section 3-3)
T-1 Software
T-2 Cabinet version
T-3 Push button test
T-4 All on display test
T-5 Segments test
T-6 Digits test
T-7 Decimal points test
T-8 LED test
T-9 Factory Use
T-10 Air temperature - user calibration/offset/highest value
T-11 Factory Use
T-12 Water heater temperature - user calibration/offset/highest
value
T-13 Humidity - circuit calibration
T-14 Humidity sensor – calibration/offset; specific value sent
with each humidity sensor
T-15 Humidity- user calibration/offset/highest value
T-16 CPU° - control temperature - highest value
T-17 Factory Use
T-18 Outputs/Inputs; on outputs steps use the four hidden
buttons [1-4] to toggle on outputs; [1] - vent motor,
[2] - auto fill solenoid valve, [3] - circulation fan,
[4] - water heater, [5] - air heater
T-19 Total init – initialization of programming areas and
statistics
moves you forward through the above selections and
moves you backwards through the selections.
2-2. TECH MODE
SECTION 2. LEVEL 2 PROGRAMMING
2-1. INTRODUCTION
Feb. 2011
Содержание AHC-990
Страница 2: ......
Страница 3: ......
Страница 49: ...Model AHC 990 993 3 27 Feb 2011 ...
Страница 52: ...Model AHC 990 993 3 30 March 2011 ...
Страница 65: ......